CHANGING PROGRAM SCHEDULES
OPERATION & PROGRAMMING
1. Press twice to enter program setting mode.
Start time of the WAKE event is flashing.
2. Press
or to adjust the start time
3. Press
, HEAT setting flashes. Press or
to adjust the heat setting.
4. Press , COOL setting flashes. Press or
to adjust the cool setting.
5. Press
, CLEAN AIR/FAN setting flashes. Press
or to adjust the clean air/fan setting.
6. Press
to advance the next event, and repeat
steps 2-6 for LEAVE, RETURN and SLEEP events.
7. Press
to advance to the next day. Repeat
steps 2-6 for each day of the week.
8. Press
to end. “DONE” will display.
The thermostat will return to normal mode if no button
is pressed in 3 seconds.
PROGRAM SCHEDULE OVERRIDES (TEMPORARY, PERMANENT, AWAY, HEAT BLAST)
OPERATION & PROGRAMMING
Temporary program override
Press
or to immediately adjust the
temperature. This will temporarily override the
temperature setting for the current programmed time
period. The new temperature setting will be maintained
until the next time period of the programmed schedule.
To cancel the temporary override, press
twice.
Permanent hold
Press
to permanently hold the temperature at
its current setting. This will override the temperature
settings for all time periods of the programmed schedule.
With the thermostat in permanent hold, the thermostat
temperature can be manually adjusted and will stay at
that setting until the hold is cancelled.
To cancel the permanent hold press
.