Ice Maker Water Filtration System
Model P6GEG2KL, P6KG2KL, P6WG2KL Capacity 2000 Gallons (7571 Liters)
This system has been tested according to NSF/ANSI Standards 42 for the reduction of the substances listed below. The concentration of the
indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the
system, as specied in NSF/ANSI Standards 42.
Substance Reduction
Aesthetic Effects
NSF Reduction
Requirements
Average
Inuent
Inuent Challenge
Concentration
Maximum
Efuent
Average
Efuent
Minimum %
Reduction
Average %
Reduction
Chlorine Taste/Odor 50% reduction 1.9727 mg/L 2.0 mg/L ± 10% 0.71 mg/L 0.7788 mg/L 70.2 72.81
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.50 gpm (1.89 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 2000 gallons (7571 liters).
System tested and certified by NSF
International against NSF/ANSI
Standard42 for the reduction of
Chlorine Ta ste and Odor.
PERFORMANCE DATA SHEET
It is essential that operational, maintenance, and lter
replacement requirements be carried out for the product to
perform as advertised.
Use replacement lter P6RFWG2K, P6RFGEG2K, P6RFKG2K,
Part Number ICE2.
Style 1 – When the water lter status display changes from
“GOOD” to “ORDER,” order a new lter. When the lter
indicator reads “REPLACE,” it is recommended that you
replace the lter.
Style 2 – Press FILTER to check the status of your water lter.
If the lter indicator light is yellow and the words “ORDER
FILTER” appear on the display screen, order a new lter. If the
lter indicator light is red, it is recommended that you replace
the lter.
These contaminants are not necessarily in your water supply.
While testing was performed under standard laboratory
conditions, actual performance may vary.
The product is for cold water use only.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system.
Refer to the “Warranty” section for the Manufacturer’s name,
address and telephone number.
Refer to the “Warranty” section for the Manufacturer’s limited
warranty.
Application Guidelines/Water Supply Parameters
Water Supply City or Well
Water Pressure 30 - 120 psi (207 - 827 kPa)
Water Temperature 33°- 100°F (0.6° - 37.8°C)
Service Flow Rate 0. 50 gpm (1.89 Lpm) @ 60 psi