Instructions for the installer
41
9.3 Adjusting the minimum setting for natural gas
Light the burner and turn it to the minimum
position. Extract the gas tap knob and turn the
adjustment screw at the left side of the tap
(indicated in the figure) until the correct minimum
flame is achieved.
Refit the knob and verify that the burner flame is
stable (when turning the knob rapidly from the
maximum to the minimum position the flame must
not go out).
Repeat the operation on all the gas taps.
9.4 Adjusting the minimum setting for LPG
To adjust the minimum setting with LPG, you must tighten the screw inside or
next to the tap rod (depending on the model) fully in a clockwise direction.
The bypass diameters for each individual burner are shown in table “9.2 Burner
and nozzle characteristics table”.
After adjustment with a gas other than the preset one, replace the label on the
bottom of the appliance with the label corresponding to the new gas. This label
can be obtained from the nearest Authorised Service Centre or supplied where
envisaged.
9.5 Arrangement of the burners on the hob
HOB BURNERS
1 Auxiliary
2 Rapid
3 Double crown
9.6 Lubrication of gas taps
Over time the gas taps may become difficult to turn and get blocked. Clean them
internally and replace the lubrication grease. This procedure must be carried
out by a specialised technician.