Instructions for the installer
38
8.2 Connection with a rigid copper hose
The connection to the gas supply network must be made in
such a way that it does not cause stresses of any type on the
appliance.
Carefully screw the adapter unit 3 with double cone to the gas
connector 1 of the appliance, placing the supplied seal 2
between them.
8.3 Connection to LPG
Use a pressure regulator and make the connection on the gas cylinder following
the guidelines set out in the regulations in force.
Make sure that the supply pressure complies with the values indicated in the
table in “9.2 Burner and nozzle characteristics table”.
2
1
3