28
BEFORE YOU CALL
Visit our web site at
www.frigidaire.com
1-800-944-9044 (United States)
1-800-265-8352 (Canada)
CONCERN CAUSE SOLUTION
AUTOMATIC ICE MAKER
Ice maker is
not making any
ice.
Ice maker is turned off.
Refrigerator is not
connected to water line
or water valve is not
open.
The water supply line is
kinked.
Thewaterlterisnot
seated properly.
Thewaterltermaybe
clogged with foreign
material.
Turn on ice maker. Press and hold the “ON-
OFF” button for three seconds until the
indicator light is on.
Connect the unit to the household water
supply and ensure the water valve is open.
Ensure that the supply line does not kink
when the refrigerator is pushed into place
against the wall.
Removeandre-installthewaterlter.
Remove by rotating it counter-clockwise (to
the left) 90 degrees to release it. Re-install
byslidingitintothelterhousingasfaras
it will go with the grip end horizontal. Push
lightlyinwardonthelterwhilerotatingit
clockwise(totheright).Thelterwillthen
pull itself inward as it is rotated. Rotate the
lter90degreesuntilitstopsandthegrip
end is vertical. You may be able to feel a
verylightclickasthelterlocksintoplace.
If water dispenses slowly or not at all, or
ifthelterissixmonthsoldorolder,it
should be replaced.
Ice maker is
not making
enough ice.
Ice maker is producing
less ice than you expect.
Thewaterltermaybe
clogged with foreign
material.
The water supply line is
kinked.
Saddle valve on cold
water pipe is clogged
or restricted by foreign
material.
Heavytrafc,opening
or closing of the doors
excessively.
Freezer control is set too
warm.
The ice maker produces approximately 2.5
to 3 pounds every 24 hours depending on
usage conditions.
If water dispenses slower than normal,
orifthelterissixmonthsoldorolder,it
should be replaced.
Ensure that the supply line does not kink
when the refrigerator is pushed into place
against the wall.
Turn off household water line valve.
Remove valve. Ensure that valve is not
a self-piercing saddle valve. Clean valve.
Replace valve if necessary.
Press Quick Freeze to temporarily increase
ice production rate. (Does not apply to
Frigidaire Professional.)
Set freezer control to colder setting to
improve performance of the ice maker.
Allow 24 hours for temperature to stabilize.