S-DD2-L FLUSH TOP20
EN
MODEL SDD2-L GLASS VERSION
A: Light ON/OFF key
The light switches on and off only when the
carriage is fully OPEN.
Pressing this button with the carriage closed
will cause the carriage to open and then the
light will switch on .
The button also serves to switch off the light
if it is on.
B:
ON/OFF key
This starts the extraction carriage upward
movement and when it is fully open, it sets the
second extraction speed.
With the carriage open: it switches off the mo-
tor and if on, the light; then it retracts the ex-
traction carriage.
C:
(-) Key
This reduces the speed of the extractor motor
from the 4th speed until the motor switch-
es off, without closing the pull-out car-
riage.
D:
Indicators
•This signals the speed setting, by onlythe
relevant LED switching on.
•This signals that all filters have been satu-
rated by all LEDs switching on.
E:
(+) Key
This increases the speed of the extractor mo-
tor, from 1st to 4th speed, without moving the
extractor panel.
F:
Timer
10 min after setting, it serves to stop the ex-
tractor motor, close the carriage and switch
the lights off, if they are on. The set function is
signalled by the flashing LEDs “D” for the set
speed. The timer can be cancelled by press-
ing the key again.
Other functions:
Automatic turn off:
After 4 hours of continuous working from the
last setup, the appliance turns off and closes
automatically.
Grease filters saturation:
After 30 hours of working, the speed indica-
tors “D” will all flash simultaneously, signaling
the grease filters saturation.
To reset this alarm, hold down the “TIMER
button for at least 3 seconds, while the car-
riage is open.
Calibration:
The cooker-hood carries out its self-calibra-
tion every 3 complete cycles of its extractable
unit.
By pushing the “TIMER” key 6 times consec-
utively (MAX break between one push and the
other is 3 sec.) all the leds will flash and the
calibration will be reset.
After the next 3 cycles the downdraft will carry
out its self-calibration.
Stand-by:
When the extractable unit is closed and the
light is switched off, the control panel, after
6 seconds, activates the Stand-by function,
reducing the brightness of the leds.
This function can be stopped by pressing ON/
OFF or LIGHT key.
HOW THE COOKER
HOOD WORKS
Loading ...
Loading ...
Loading ...