Ice maker
Fault Possible cause Remedial action
Freezer compartment door
was open for a long time;
temperature is no longer
reached.
The evaporator (refrigeration unit) in
the NoFrost system is covered in
thick ice and can no longer be auto-
matically defrosted.
To defrost the evaporator, remove the frozen
food with the compartments, insulate it well and
store it in a cool location.
Switch off the appliance and move it away from
the wall. Leave the appliance door open.
After approximately 20 minutes, the melted water
begins to run into the evaporation pan at the rear
of the appliance.
To keep the evaporation pan from overflowing,
mop up the condensation with a sponge.
, CAUTION:
RISK OF BURNS:
Parts may be hot. Proceed with caution.
The evaporator is defrosted when no more water
is running into the evaporation pan. Clean the
interior. Switch the appliance back on.
Fault Possible cause Remedial action
The ice maker doesn’t
work.
Ice maker is not connected
to the mains supply.
Call customer service.
Ice maker does not contain any
fresh water.
Ensure that the water is properly connected.
The freezer compartment tempera-
ture is too warm.
Check freezer compartment temperature and,
if required, set slightly colder.
The ice maker doesn't work. The water supply is switched off. Turn the water supply on.
The ice maker is switched off Switch on the ice maker.
The fill level gauge (metal hook) is
blocked.
Remove the blockage.
Ice cubes are watery.
Ice cubes have melted.
Remove the ice cube container, empty and rub
dry.
Freezer compartment door is open. Close the door.
Power failure. Check whether the power is on.
Ice cubes in the ice cube
container stick together.
Normal behavior for longer storage
periods.
Remove the ice cubes.
The ice cubes are too
small.
Water pressure too low. Ensure the minimum pressure of 29 psi (2 bar).