BARBECUE POSITIONING
This appliance shall only be used in an above ground open-air situation with natural ventilation, without
stagnant areas, where gas leakage and products of combustion are rapidly dispersed by wind and natural
convection.
Any outdoor enclosure in which the appliance is used shall comply with one of the following:
1. An enclosure with walls on all sides, but at least one permanent opening at ground level and no overhead
cover. See Fig 1.
2. Within a partial enclosure that includes an overhead cover and no more than two walls. See Fig. 2 & 3.
3. Within a partial enclosure that includes an overhead cover and more than two walls, the following shall
apply:
At least 25% of the total wall area is completely open; and
At least 30% of the remaining wall area is open and unrestricted. See Fig. 4 & 5.
4. In the case of balconies, at least 20% of the total of the side, back and front wall areas shall be and
remain open and unrestricted.
The following diagrams provide a diagrammatic representation of outdoor areas. Rectangular areas have been
used in these figures - the same principles apply to any other shaped area.
Figure 1 - Enclosure with walls on all sides but Figure 2 - Partial Enclosure with overhead cover and no
overhead cover no more than two walls
Figure 3 - Partial Enclosure with overhead cover and Figure 4 - Open side at least 25% of total wall area.
no more than two walls. 30 % or more in total of the remaining wall area is open
and unrestricted.
Figure 5 - Open side at least 25% of total wall area. 30 percent or more in total of the remaining wall area is open and
Unrestricted