Cut out dimensions
For Model
Width
Depth
EMPV-30GC20 EMPV-30GC21 EMPV-30GC26
28.58in
18.54in
EMPV-36GC22 EMPV-36GC23 EMPV-36GC24
EMPV-36GC25
34.68in
19.33in
EMPV-36GC27
32.83in
18.66in
EMPV-24GC28
22.08in
18.54in
Technical Data
Burner configuration
NG
LPG
Nozzles Dia. (mm)
Btu/hr
Nozzles Dia. (mm)
Btu/hr
Ultra-rapid burner
1.68
13000
1.10
13000
Rapid burner
1.57
10200
0.96
10200
Semi rapid burner
1.16
6000
0.76
6000
Auxiliary burner
0.91
3800
0.60
3800
Different models have different total heat input, please refer to page 3,page 4 & page 5.
Gas Type Manifold pressure :
NG gas pressure at 4.0 in wc
LPG gas pressure at 10 in wc.
Maximum Gas Supply Pressure: 14 in wc.
Gas supply pressure for checking regulator setting:
NG gas pressure at 5.0 in wc
LPG gas pressure at 11 in wc.
Important safety requirements
Location
The cooktops may be located in a kitchen, a kitchen/diner or bed sitting room, but not in a bathroom,
shower room or garage. Before making the cut out in the worktop ensure that there is a minimum
distance of 2.17” between the rear edge of the cooktops and the wall. A minimum distance of 3.94”
must be left between the side edges of the cooktops and any adjacent cabinets or walls. The minimum
distance combustible material can be fitted above the cooktops in line with the edges of the cooktops is
18”. If it is fitted below 18” a space of 1.97” must be allowed from the edges of the cooktops. The
minimum distance combustible material can be fitted directly above the cooktops is 30”. Maximum
depth for the overhead cabinets is 13”. The distance from the front edge of the cooktop to the front edge
of the countertop should be 3.0”.The distance between the closet should be 23.62” (not less than the
depth of the cooktop itself) (see Figure 12)
Notice that a horizontal separation below the base of the hotplate is needed.
The minimum distance between this separation shall not exceed 5.90”.
11