Loading ...
Loading ...
Loading ...
12
INSTALLATION INSTRUCTIONS
Connecting the cooktop to the mains power supply
IMPORTANT!
●
This cooktop must be connected to the mains power supply only by a suitably
qualified person.
●
This cooktop must be earthed.
●
Before connecting the cooktop to the mains power supply, check that:
●
the domestic wiring system is suitable for the power drawn by the cooktop
●
the voltage corresponds to the value given on the rating plate
●
the power supply cable sections can withstand the load specified on the rating plate.
●
To connect the cooktop to the mains power supply, do not use adapters, reducers, or
branching devices, as they can cause overheating and fire.
●
The power supply cable must not touch any hot parts and must be positioned so that its
temperature will not exceed 75
o
C at any point.
Power supply
CE302C 2900W @ 220-240V~ (12.6 A)
CE604L 6000W @ 220-240/380-415V 3N~ (26 A)
CE604C 6400W @ 220-240/380-415V 3N~ (27.8 A)
CE905C 8400W @ 220-240/380-415V 3N~ (36.5 A)
IMPORTANT!
Check with an electrician whether the domestic wiring system is suitable without
alterations. Any alterations must only be made by a qualified electrician.
Connection diagrams
Single-phase
connection
CE604L, CE604C, CE905C
CE302C
Two-phase
connection
Three-phase
connection
PE
1
2
3
4
5
N (L2)L1
220 - 240 V
PE
1
2
3
4
5
380 - 415 V 3N
N
L3L1 L2
PE
1
2
3
4
5
380 - 415 V 2N
N
L1 L2
PE
N(L )
L1
2
Loading ...