2 ZONE T6R SMART THERMOSTAT
T6R-2Z-EN0H 8603 NL01 R0718
9
OPENTHERM® COMMUNICATION
OpenTherm® is a manufacturer independent communication protocol between modulating appliances (boilers, air heaters
and heat recovery units) and room thermostats.
Via the OpenTherm® protocol, the Receiver box of the T6 / T6R thermostat constantly communicates with the connected
appliance.
Modulating
The T6/T6R thermostat controls, via the Receiver box, the OpenTherm® communicating appliance modulating. This means
that, depending on the heat demand, the burner capacity is adjusted in the appliance. This creates a very accurate control
of the room temperature.
On top of that, this method of temperature control is more energy-efficient and environmentally friendly.
Low Load Control
When a boiler is no longer capable of modulating back it will stop the burner and then will be a cycling on it's own
continuously during this low control setting (requested water temperature).
In order to have a proper performance and to switch the pump on/off as well we created low load control. This is cycling
between off and min modulation level.
The cycle rate is related to the time the water temperature is cooling off below the control setpoint (demand) and the on
time of the boiler to get heated to the control setpoint.
It's an algorithm which optimizes the cycle rate and tries to get the boiler on for the longest time.
Hot water control
Most Combi-boilers have a small internal storage for hot tap water. By keeping a number of liters of hot water, the
appliance can supply hot tap water directly without having to heat it up first. With a longer period of none use or absence,
for example sleep or holiday, the hot water storage does not have to be kept at a high temperature.
The T6/T6R thermostat can provide additional savings here. With the last programmed period (sleeping)
the hot water status can easily be switched to a saving level or completely be switched off.
With these Combi-boilers, a menu "Hot water during sleep" (on/off) will be available in the installer menu (page 6).
OpenTherm® data
De T6/T6R thermostat offers the ability to view some appliance data via de OpenTherm® communicatie.
See table on page 6 which data can be viewed.
Note: Depending on the connected appliance, more or less data is displayed on the T6/T6R thermostat and certain
settings of the appliance may or may not be changed from the thermostat. Refer to the instruction manual of the
appliance for specific information.
Advanced menu item
Default
Data / Options
OpenTherm
Submenu
(read only)
- Low Load Control
- Control Setpoint Requested supply temperature
- Supply Water Temperature Actual supply water temperature
- Return Water Temperature Actual return water temperature
- Max Supply Water Temperature
- Hot water Temperature Actual hot water temperature
- Hot Water Setpoint
- Actual Power Actual power of appliance
- Water Pressure
Hot Water Overnight
1
0= OFF, 1 = ON
Hot Water Setpoint
60
30 tot 75 °C (appliance depending)
Max Supply Water Setpoint
90
30 tot 90 °C (appliance depending) - future
Low Load Control
1
0= OFF, 1 = ON