Loading ...
Loading ...
Loading ...
2 ZONE T6R SMART THERMOSTAT
T6R-2Z-EN0H 8603 NL01 R0718
8
Special Features
Description
Heat Range
The normal lower temperature limit of 5
o
C can be increased up to 21
o
C to protect the
inhabitants from cold conditions. This is a useful feature aimed at supporting the elderly,
children and disabled inhabitants.
The normal upper temperature limit of 35
o
C can be reduced down to 21
o
C to save energy. This
feature is useful for leased homes and apartments.
Schedule options
The thermostat has 2 default schedules: daily (every day) and 5+2 (week + weekend days)
Optimisation (optimal
start, optimal stop and
delayed start)
Optimal Start: learns how long it takes your system to reach the programmed temperature. It
turns on the heating system earlier to make sure it’s comfortable at the scheduled time.
Optimal Stop: Saves energy and money by switching off a little bit earlier than the normal
programmed time. If the home is up to temperature, it will not notice the effect on the
temperature, but will show a difference in the fuel bill.
Delayed start: Saves energy by slightly delaying the start of heating depending on the
difference between the scheduled temperature and the actual room temperature
Clock setting
Change display format (default 24hr) and adjust time and date.
When connected to Internet time and date will be synchronized
Low Load Control
If the Receiver box is connected to an OpenTherm appliance this setting is used in the demand
control. When an appliance is no longer able to modulate lower the control switches from
modulating control to low/off control.
Temperature Offset
If the Thermostat is located in a hot/cold location and cannot be moved because of wiring then
the measured/ displayed temperature can be adjusted by +/- 1,5
o
C. This feature is useful if the
homeowner wants the reading to match another appliance temperature display.
Binding
Menu to bind the Thermostat and the Receiver box, test the RF signal strength of the radio
communication and to clear an existing binding.
Reset
Menu to reset the thermostat back to factory default settings, reset the schedule to default
settings, reset the Wi-Fi and Homekit settings.
Failsafe
When the radio communication between the Thermostat and Receiver box is lost for longer
than 1 hour the Receiver box will start to cycle the demand 20% on / 80% off.
Menu item
Default
Options
Language
English
English, Francais, Espanol, Deutsch, Nederlands, Italiano
OpenTherm
-
OpenTherm boiler data when a vailable (see OpenTherm communication)
Cycle rate
6
3,6,9 or 12
Min on time
1 minute
1, 2, 3, 4 or 5 minutes
Heat range
Min = 5.0
Max = 37.0
Min: 5.0°C to 21.0 °C, Max:21.0°C to 37.0 °C
Schedule options
Daily
1 = daily schedule, 2 = 5+2 days schedule
Optimisation
Opt.start on
Opt.stop off
Opt start: 0 = off, 1 = on, 2 = Delayed start
Opt stop: 0 = off, 1 = on
Clock
Format: 24h
Time: --:--
Date: 01/09/2016
Clock format: 1 = 12h, 2 = 24h
Setup time and date
Low Load Control
ON
0= Off, 1 = On
Temperature offset
0.0
-1.5°C to 1.5 °C
Bind
-
Bind, check RF and clear bind.
Adv Reset
-
Factory, schedule, Wi-Fi and Homekit reset
Failsafe
OFF
0= Off, 1 = On
ADVANCED MENU
To enter the Advanced menu (installer set-up):
Press the menu key for 5 seconds.