8 49-7845 Rev. 0
Installation Instructions
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT – Save these
instructions for local inspector’s use.
IMPORTANT – Observe all governing
codes and ordinances.
Note to Installer – Be sure to leave these
instructions with the Consumer.
Note to Consumer – Keep these instructions for
future reference.
Skill level – Installation of this appliance requires
basic mechanical skills.
Completion time Approximately 1 hour
We recommend that two people install this product.
Proper installation is the responsibility of the
installer.
Product failure due to improper installation is not
covered under the Warranty.
You MUST use all supplied parts and use proper
installation procedures as described in these
instructions when installing this air conditioner.
Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: GEAppliances.com
ELECTRICAL REQUIREMENTS
These models require a 115/120-volt AC or a
230-volt AC, 60-Hz grounded outlet protected
with a 15-amp time-delay fuse or circuit
breaker.
The 3-prong grounding plug minimizes the possibility
of electric shock hazard. If the wall outlet you plan to
use is only a 2-prong outlet, it is your responsibility to
have it replaced with a properly grounded 3-prong wall
outlet.
Power cord includes a current interrupter device. A
test and reset button is provided on the plug case. The
device should be tested on a periodic basis by first
pressing the TEST button and then the RESET button
while plugged into the outlet. If the TEST button does
not trip or if the RESET button will not stay engaged,
discontinue use of the air conditioner and contact a
qualified service technician.
INSTALLATION REQUIREMENTS
For new construction, install the Haier Wall Sleeve
HTTWSB.
Remove old air conditioner and inspect sleeve for
the following:
Installation - Make sure that sleeve is securely
installed and in sound structural condition.
Dimensions - Measure the size to make sure the air
conditioner will fit.
Slope - Ensure wall sleeve is level or has a rearward
slope for condensate to drain from the unit.
If pre-existing wall sleeve is suspect, it is
recommended to install Haier Wall Sleeve, model
HTTWSB, in its place.
TOOLS YOU WILL NEED
Phillips head screwdriver
Ruler or tape measure
Pencil
Level
Scissors or knife
Drill and 1/8” drill bit
CAUTION
Do not, under any circumstances, cut or remove
the third (ground) prong from the power cord.
Do not change the plug on the power cord of this
air conditioner.
Aluminum house wiring may present special
problems—consult a qualified electrician.
CAUTION
There are sharp edges that can cause serious cuts.
When lifting the air conditioner, it is HEAVY. Use 2
peoples to lift.
INSTALLATION INSTRUCTIONS
REAR
Wall Sleeve
UNIT
LEVEL
FRONT
to
ARRIÈRE
Compartiment mural
APPAREIL
NIVEAU
AVANT
1/4 po à 5/16 po
PARTE
TRASERA
Forro para pared
UNIDAD
NIVEL
PARTE
FRONTAL
a