Loading ...
Loading ...
Loading ...
40
BEFOREYOUCALL• Solutions to common problems
Problem Possible Causes Solutions
Oven portion of
appliance does not
operate.
Incorrect oven control setting. Be sure the oven control was set correctly for the requested
feature. See Setting Oven Controls section and review
instructions for the desired cooking function in this manual or
see “Entire appliance does not operate” in this checklist.
Lock feature may be active. Cancel the lock feature (some models).
Entire appliance does
not operate.
Power supply to appliance
disconnected or electrical
power outage.
Be sure appliance power cord is plugged properly to electrical
outlet. Check house circuit breaker; reset if needed. If the
electric service to the house is out, call your local electric utility
for service.
Service wiring is incomplete. Contact your dealer, installing agent or authorized service
agent for assistance.
Range is not level. Floor is not level, weak or
unstable.
If oor under range is sagging or sloping, contact a carpenter
to correct the problem.
The cooktop or oven racks are
not level.
To correct, place oven rack in center of oven. Place a bubble
(or spirit) level centered on the oven rack. Adjust by turning
leveling legs at bottom of range until the oven rack rests level.
Cabinet alignment may make
range appear not level.
Be sure kitchen cabinets are square & have sufcient room for
appliance clearance.
Cannot move
appliance easily.
Appliance must
be accessible for
service.
Carpet interferes with range. Provide sufcient space so appliance may be lifted over carpet.
Cabinets are built in too tightly
to appliance sides.
Contact builder or installer to make appliance accessible.
Convect fan makes
noise.
The convect fan may turn ON
or OFF automatically.
This is normal. On some cooking features the convect fan may
run until the feature is done or the door was opened or closed.
Convect fan turns
ON and OFF while
cooking.
Oven door is open. The convect fan will turn OFF if the oven door is opened while
any convect feature is active. Close oven door.
Convect fan turns on
with features that
should run without a
fan (some models).
For some models the convect
fan may turn ON while
preheating.
This is normal (some models).
Oven control displays
Prob ERR”.
The probe is not
recognized by the
oven control.
The probe is not fully inserted
into the probe receptacle.
Double check that the temp probe is fully inserted into probe
receptacle. Use only the probe originally supplied with range.
If the error code persists, the
probe may be damaged or the
probe cable has a short.
Remove the probe from receptacle and oven. The oven may
still be used normally without the probe. Call your authorized
service agent for a replacement probe.
Loading ...
Loading ...
Loading ...