ELECTRIC DRYER ELECTRICAL CONNECTIONS
(FOR U.S.A. ONLY)
Connecting 3-Wire Connection: Direct Wire
Use where local codes permit connecting cabinet-ground
conductor to neutral wire.
Direct wire cable must have 5 ft. (1.52 m) of extra length so dryer
can be moved if needed.
Strip 3½" (89 mm) of outer covering from end of cable. Strip
insulation back 1" (25 mm). If using 3-wire cable with ground
wire, cut bare wire even with outer covering. Shape ends of wires
into a hook shape.
Connecting Neutral Wire
1. Loosen or remove center terminal block screw (A).
2. Place hooked end (hook facing right) of neutral wire (white or
center wire) (D) cable under center terminal block screw (A).
Squeeze hooked end together. Tighten screw.
3. Place hooked ends of remaining direct wire cables (hooks
facing right). Squeeze hooded ends together and tighten
outer terminal block screws (F). Finally, re-install terminal
block cover and tighten hold-down screw. Tighten screws.
Go to “Complete Installation” section.
A
D
A
F
F
Connecting 3-Wire Connection: Optional
Use for direct wire or power supply cord where local codes
do not permit connecting cabinet-ground conductor to
neutral wire.
Connecting Neutral Wire
1. Remove center terminal block screw (A). Also, remove neutral
ground wire (B) by removing external ground conductor
screw (C).
2. Connect neutral ground wire (B) and neutral wire (white or
center) (D) of power supply cord/cable under center terminal
block. Tighten screw.
3. Connect remaining wires under outer terminal block. Tighten
screws (F).
4. Connect a separate copper ground wire (G) under the
external ground conductor to screw (C) an adequate ground.
Finally, re-install terminal block cover and tighten hold-down
screw. Go to “Complete Installation” section.
A
C
B
D
F
F
G
C