Loading ...
Loading ...
Loading ...
The igniter does not spark.
Possible fault Solution
The circuit breaker has tripped. Re-set the circuit breaker. Contact an
electrician for assistance if in doubt.
Food has deposited itself between the
ignitor and the burner cap.
See "Cleaning and care".
Food has deposited on the ignition
safety control.
See "Cleaning and care".
For safety reasons, after a spill on the combiset you may need to wait approx. 5
minutes before you are able to reignite the burner. Wait 5 minutes and ignite the
burner as usual.
Frequently asked questions
22
Loading ...
Loading ...
Loading ...