Direct Wire Connection
WARNING
Fire Hazard
Use 10 gauge copper wire.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal.
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining 2 supply wires to remaining
2 terminals.
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or
electrical shock.
Direct Wire Strain Relief
IMPORTANT: Use a conduit strain relief (not supplied).
3. Attach direct wire cable to strain relief
Put direct wire cable through the strain relief. The strain
relief should have a tight fit with the dryer cabinet and be
in a vertical position. Tighten strain relief screw against the
direct wire cable.
3-wire direct connection:
Go to “3-Wire Direct Wire Connection.”
4-wire direct connection:
Go to “4-Wire Direct Wire Connection.”
If your wiring looks like this:
2. Attach direct wire strain relief
A
B
Put the strain relief (B) through the hole below the terminal
block opening (A). Press the strain relief from bottom to fit into
the hole. Make sure that strain relief is fitted properly in the
hole.
1. Remove existing strain relief
With a flat-blade screwdriver, flatten the three tabs on the
band at the top of the strain relief. Pull out strain relief.