CONNECTION OF THE HOB FOR ILD906G5 AND ILD786G5
Mains Connection Cable diameter Cable Protection calibre
230V~ 50/60Hz 1 Phase + N 3 x 4 mm²
H 05 VV - F
H 05 RR - F
40 A *
400V~ 50/60Hz 2 Phases + N 4 x 2.5 mm²
H 05 VV - F
H 05 RR - F
25 A *
400V~ 50/60Hz 3 Phases + N 5 x 1.5 mm²
H 05 VV - F
H 05 RR - F
16 A *
* calculated with the simultaneous factor following the standard EN 60 335-2-6/1990
Connection of the hob
Setting up the configurations:
For the various kinds of connection, use the brass bridges which are in the box next the terminal
Monophase 230V~1P+N
Put the 1
st
bridge between terminal 1 and 2, the 2
nd
between terminal 2 and 3 and the 3
rd
between 4 and 5.
Attach the earth to the terminate “earth”, the neutral N to terminal 4 or 5, the Phase L to one of
the terminals 1,2 or 3.
Biphase 400V~2P+N
Put the 1
st
bridge between terminal 1 and 2, the 2
nd
between terminal 4 and 5
Attach the earth to the terminate “earth”, the neutral N to terminal 4 or 5, the Phase L1 to the
terminals 1or 2 and the Phase L2 to the terminal 3.
Triphase 400V~3P+N
Put a bridge between terminal 4 and 5.
Attach the earth to the terminate “earth”, the neutral N to terminal 4 or 5, the Phase L1 to the
terminals 1, the Phase L2 to the terminal 2.and the Phase L3 to the terminal 3.
Caution! Be careful that the cables are correctly engaged and tightened.
We cannot be held responsible for any incident resulting from incorrect co
nnection or
which could arise from the use of an appliance which has not been earthed or has been
equipped with a faulty earth connection.