For typical under counter installation of an electric built-in oven see Figure below.
Only certain cooktop models may be installed over
certain built-in electric oven models. Approved
cooktops and built-in ovens are listed by the MFG
ID number and product code (see the insert sheet
included in the literature package and cooktop
installation instructions for dimensions).
To reduce the risk of
personal injury and
tipping of the wall
oven, the wall oven
must be secured to
the cabinet (s) by
mounting brackets.
208/240 Volt junction
box for built-in oven..
Approx. 3"
(Z5 cm)
Note 1
Cut an opening in wood base minimum 4" x 4"
(10.2 X 10.2 cm), 2" (5 cm) from left side filler
panel, to route armored cable to junction box.
Note 1: 4" x 4" (10.2 X 10.2 cm) opening to route
armored cable from cooktop to junction box.
Approx. 3", j
(z5cm)
208/240Volt
junction box
for Cooktop
Cabinet side filler
panels are necessary
to isolate the unit from
adjoining cabinets.
Cabinet side filler
height should allow for
installation of approved
cooktop models
36" Min.
(9!.4 cm) Min.
Unit will
overlap cutout
(minimum)
edges by I"
(2.5cm) 41/2" (11.5cm)
Max. _
3/4" (1.9 cm) plywood,
installed on two runners,
flush with toe plate.
Base must be capable of
supporting 150 pounds (68
kg) for 27" models and
200 pounds (90 I<g) for
30" models.
If no cooktop is
installed directly
over the oven unit, 5"
(12.7 cm) maximum
is allowed above the
floor.
CUTOUT DIMENSIONS
wmTM MIME GNT
27" (68.6 cm) 247/8" (63.2 cm) Min. 231/2" (59.7 cm) 271/4 '' (69.2 cm) Min.
Wall Oven 251/4" (64.1 cm) Max. Min. 281/4" (71.8 cm) Max.
30" (76.2 cm) 281/2" (72.4 cm) Min. 231/2" (59.7 cm) 271/4" (69.2 cm) Min.
Wall Oven 29" (73.7 cm) Max. Min. 281/4" (71.8 cm) Max.
Figure 10- TYPICAL UNDER COUNTER iNSTALLATiON OF A SINGLE ELECTRIC BUlLTqN OVEN
WITH AN ELECTRIC COOKTOP MOUNTED ABOVE