Loading ...
Loading ...
Loading ...
9
SYMPTOM POSSIBLE CAUSE
Spark failure
(1) Faulty igniter
(2) Incorrect spark gap
(3) Loose or faulty connections
Failure to ignite even
with spark present
(1) No gas
(2) Incorrect injectors
(3) Incorrect gas type
(4) Air in gas lines
(5) Faulty thermocouple
(6) Faulty tilt switch
Dull or uneven
burners
(1) Partially blocked injectors
(2) Burner venturi blocked
(3) Dirty burner tiles
Burner ashing back
REMEDY
Replace
Reset to 4.5mm
Check with meter
Check supply
Replace injectors
Check gas for which unit was
intended
Purge all lines
Replace ODS
Replace
Clean or replace injectors
Check and clean
Clean with compressed air
Replace
Replace injector
Tighten
Clean with compressed air or a
vacuum cleaner
(1) Cracked burner tile
(2) Faulty or incorrect injector
(3) Injector loose
Very high pilot ame
(1) Pilot ports partially blocked
Please No
te:
Discolourin
g of
the heater tile face is a natural consequence of the gas combustion
process.
FAULT FINDING
SERVICING
Servicing shall be carried out, only by an authorised person. OMEGA ALTISE recommends that this Radiant Heater
be serviced every 24 months to ensure the heater continues to operate in a safe
and at its optimum condition.
This is part of general maintenance and any costs incurred are not covered by warranty.
If the unit fails to ignite after following these instructions, contact your authorised OMEGA ALTISE
service centre.