9
Vent Tube
NOTE: Do not pinch, kink or damage the vent tube. Check that it
is not damaged, or pinched or kinked between the cabinet and
the ice maker.
15. Attach ½" ID x 10 ft (3 m) drain tube to pump discharge tube.
See “Parts Locations” illustration.
16. Connect ice maker to water supply and install ice maker as
specied by the product installation instructions.
17. Check all connections for leaks.
18. Plug in ice maker or reconnect power.
19. Turn on ice maker.
20. Wait for rinsing cycle, approximately 5 minutes, to be sure the
ice maker is operating properly.
Drain Connection
Gravity Drain System
Connect the ice maker drain to your drain in accordance with all
state and local codes and ordinances. If the ice maker is provided
with a gravity drain system, follow these guidelines when
installing drain lines. This will help keep water from owing back
into the ice maker storage bin and potentially owing onto the
oor, causing water damage.
Drain lines must have a minimum of
5
8
" (15.88 mm) inside
diameter.
Drain lines must have a 1" drop per 48" (2.54 cm drop per
122 cm) of run or ¼" drop per 12" (6.35 mm per 30.48 cm) of
run and must not have low points where water can settle.
The oor drains must be large enough to accommodate
drainage from all drains.
The ideal installation has a standpipe with a 1½" (3.81 cm) to
2" (5.08 cm) PVC drain reducer installed directly below the
outlet of the drain tube as shown. You must maintain a 1"
(2.54 cm) air gap between the drain hose and the standpipe.
Do not connect the outlet end of the drain tube to a closed
pipe system to keep drain water from backing up into the ice
maker.
IMPORTANT: A drain pump is necessary when a oor drain is not
available. A Drain Pump kit, Part Number 1901A, is available for
purchase.
Side View
A
B
A. Vent tube
B. Clamps and screws
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
1" (2.5 cm)
20" (50.80 cm)
1⁷⁄₈"
(1.9 cm)
B
D
C
A
2" - 1¹⁄₂"
(5 cm - 3.8 cm)
A. Drain hose
B. 1" (2.54 cm) air gap
C. PVC drain reducer
D. Center of drain should be 20" (50.8 cm)
from front of door, with or without the ¾"
(1.91 cm) panel on the door. The drain
should also be centered from left to right
(8
13
16
" from either side of the ice maker).