Ionizer function
The ionizer function releases negative ions into the air. This function is switched off by default. To activate it,
briefly press button 10.
Timer / delayed start
If the appliance is on: you can use this button to define the operating duration. Briefly press the button to select
the number of operating hours desired (1, 2, 4 or 8) and the appliance will automatically turn off at the end of
the selected period.
If the appliance is off: briefly press the button to set the appliance to turn on in a certain number of hours (1, 2, 4 or
8).
3D pure air function (adjustable grid)
You can adjust the position of the air outlet grid manually, as desired. For an optimum, even flow of purified air
in the room, set the angle to 45°; for maximum comfort, set the angle to 90°.
Control Panel Lock
The lock system prevents the purifier from being accidentally mis-set during operation.
To activate it, press the button (7) for 3 sec until the locked control panel indicator turns on. To exit this mode,
press the button (7) again for 3 seconds, until the indicator turns off. When selected, the other buttons are locked.
Always switch the appliance off with the button (9) and unplug it before conducting any maintenance
operation.
You can clean the appliance with a slightly damp cloth.
IMPORTANT: Never use abrasive products which could damage your appliances appearance.
Filters
This data is based on an average use of around 8 hours per day at lowest speed of Auto Day Mode.
The recommended frequency for cleaning and replacing the filters may vary depending on the duration of use
and the operating environment.
- The light indicates when the pre-filter needs cleaning.
- The light indicates when the active carbon filter needs replacing.
- The light indicates when the HEPA filter needs replacing.
- The light indicates when the color of the NanoCaptur filter needs checking.
The NanoCaptur filter contains translucent granules which change color according to the formaldehyde absorption
rate. Refer to the color chart on the inside of the panel or the filter itself to establish the filter saturation rate. Once the
saturation rate has reached its maximum, the filter must be replaced. You have to check the filter saturation rate every
six months.
The pre-filter can be re-used: remove the dust using a vacuum cleaner or wash with water.
CAUTION:
The appliance's efficiency can be reduced if the pre-filter is not cleaned regularly.
Never use a pre-filter that is still damp.
MAINTENANCE
Filter Action Cycles
Pre-filter Clean Every 2 to 4 weeks
Active carbon filter Replace Every 12 months
HEPA filter Replace Every 3 years
NanoCaptur filter Replace
Color changing
(see Color chart on filter)