Installation
36
Nozzles which are not provided are available at Authorised Service Centres.
8 LPG G30/31 AUX SR R UR
Rated heating capacity (kW)
1.0 1.75 2.9 4.0
Nozzle diameter (1/100 mm)
50 65 85 102
Pre-chamber (printed on nozzle)
----
Reduced capacity (W)
400 500 800 1600
Rated capacity G30 (g/h)
73 127 211 291
Rated capacity G31 (g/h)
71 125 207 286
9 LPG G30/31 AUX SR R UR
Rated heating capacity (kW)
1.0 1.8 2.9 4.0
Nozzle diameter (1/100 mm)
50 65 81 94
Pre-chamber (printed on nozzle)
----
Reduced capacity (W)
450 550 800 1600
Rated capacity G30 (g/h)
73 131 211 291
Rated capacity G31 (g/h)
71 129 207 286
10 LPG G30/31 AUX SR R UR
Rated heating capacity (kW)
1.0 1.8 2.9 3.8
Nozzle diameter (1/100 mm)
43 58 74 77
Pre-chamber (printed on nozzle)
(H2) (M) (Z) (F4)
Reduced capacity (W)
400 500 800 1600
Rated capacity G30 (g/h)
73 131 211 276
Rated capacity G31 (g/h)
71 129 207 271
11 City Gas G110
AUX SR R UR
Rated heating capacity (kW)
1.0 1.8 2.8 3.8
Nozzle diameter (1/100 mm)
145 185 260 340
Pre-chamber (printed on nozzle)
/8 /2 /3 /13
Reduced capacity (W)
400 500 800 1400
12 City Gas G120
AUX SR R UR
Rated heating capacity (kW)
1.0 1.8 2.9 3.8
Nozzle diameter (1/100 mm)
145 185 260 315
Pre-chamber (printed on nozzle)
/8 /2 /3 /13
Reduced capacity (W)
400 500 800 1400
WARNING: In the case of conversion to Town Gas G110 – 8 mbar (category
1a), do not use the burners provided, but request the special G110 burners kit
from our Technical Assistance Service.