SECTION 5 SERVICER'S TECH. INFORMATION
I
5C.
I
DIAGNOSTICS
AUTOMATIC ELECTRONIC DIAGNOSTIC
The face plate has a self-diagnostic function for the
electrical system (except input power). The face plate
monitors the electronic components and circuitsfor
correct operation. If a malfunc-
tion occurs, an error code ap-
pears in the face plate display.
The chart below shows the error codes that could
appear, and the possible defects for each code.
While an error code appears in the display, all face
plate buttons are inoperable except the SET/CLEAR
button. SET/CLEAR remains operational so the
service person can make the MANUAL ADVANCE
DIAGNOSTICS to further isolate the defect.
POSSIBLE DEFECT
CODE MOST LIKELY ,, '- LESS LIKELY
E - 1 motor inop. / wiring harness or connection to switch / switch / face plate
E - 2, E - 3 face plate
E - 4 face plate / position switch
PROCEDURE FOR REMOVING ERROR CODE FROM FACE PLATE: 1. Unplugtransformer 2. Correct
defect 3. Plug-intransformer 4. Wait for 6 minutes. The error code will return ifthe defect was notcorrected.
MANUAL ADVANCE DIAGNOSTIC
Use the following procedures to advance filter valve
through recharge cycles to check operation.
Remove top cover to observe valve rotation.
DISPLAY MUST SHOW TIME AND DAY
1. Press and _ [] for 3 seconds
until 18:88 displays.
2. Press [] todisplay position (P)
switch open or closed indicator.
If valve is in service, fill, solution draw,
backwash or fast rinse (see markings on
cam under motor), display will show...
(--), meaning the position switch is open.
[-- ]
While the valve is rotating from
one cycle to another, the display
shows (-P), meaning the posi-
tion switch is closed.
NOTE:
M
a. If itdoes not move into fill, valve motor isinopera-
tive. Check all wiring and connections.
While in manual advance, the time display automati-
cally returns to the present time of day if a button is not
pressed within 4 minutes.
3. To advance valve, press_]each time you want to
move into next cycle. (Pressingr_ while valve is
rotating has no affect.)
b=
C=
d=
-- Press and holdr_ for 3 seconds to _ 4.
move filter into fill. Verify fill water
enters solution bottle. [ - " I 5.
21
If water does not enter bottle, see "Quick-Check
Troubleshooting," page 22.
-- After 5 minutes of fill press r_to
move filter intosolution draw. (NOTE:
Advance through backwash and fast
rinse first if double backwash is pro-
grammed.) A slow flow of water to
drain begins. Verify solution draw
from the bottle.
If solution isnot drawn from bottle.., see "Quick-
Check Troubleshooting," page 22.
-- Again press [] to move filter into I " P ]
backwash. Look for a fast flow of I - - 1
water from drain hose.
I J
A slow flow indicates an obstructed top distribu-
tor, backwash flow plug, drain hose, or iron fouled
mineral bed.
-- Press [] to move filter into fast
rinse. Again look for fast drain flow.
Allow to dnse until drain water is clear, [_
with no purple color (from solution
draw test).
--To return filter to service, press[5].
Press [] to display 18:88.
Press [] to return present time and
day.