SECTION 4 OTHERTHINGSTOKNOW
I
4A.
I
DIMENSIONS/SPECIFICATIONS
BYPASS VALVES
SINGLE-PLASTIC
PULL STEM
OUTWARD
FOR
SERVICE
For
Bypass
SINGLE-BRASS
Inward
FOr PUSH
Bypass INWARD
FOR
SERVICE
3-VALVE
SERVICE
Close ByPass Valve
Open Inter & Outlet Valves
BYPASS
Open Bypass Valve
Close Inlet & Outtet Valves
Bypass
VaI,R
Outlet
inlel
Valve
55"
r
FREEBOARD
18"-22"
tank
height
47"
[
3%" inlet-outletcentedines
INLET-OUTLET
L-2o.,--4
49"
FREEBOARD isthe distance(inches
from top of the tank to top of the
mineral bed (t cuft of mineral)
CLASSIFICATION OF FILTER: .................................................................................. Household
FILTER TYPE: .............................................................................................................. Oxidizing
TYPE OF MINERAL: .......................................................................... Manganese dioxide coated
AMOUNT OF MINERAL: .............................................................................................. 1.0¢u. ft.
AMOUNT OF GRAVEL BASE: .......................................................................................... 17 Ibs
AMOUNT OF FILTER SAND: ............................................................................................ 10 Ibs
INLET WATER PRESSURE LIMITS: .......................................................................... 20-125 psi
RATED SERVICE FLOW: ............................................................................................ 8 gal/min
MAX. PRESSURE DROP AT RATED SERVICE FLOW: .................................................... 10 psi
MAXIMUM INLET WATER TEM PERATURE: .................................................................... 120°F
MINIMUM INLET WATER FLOW: ................................................................................ 420 gal/hr
MINIMUM INLET AND OUTLET PIPE SIZE: .................................................................. 3/4 inch
BACKWASH FLOW RATE: (at 35 psi inlet pressure) .................................................... 7 gal/min
MINIMUM SUPPLY WATER pH: ............................................................................................ 7.0
CAPACITY RATING:........................................................................... See Rating Decal on Filter
POTASSIUM PERMANGANATE USED EACH REGENERATION:
at "A" setting on Tube: ................................................................................................ 2 ounces
at "B" setting on Tube: .................................................................................................. 1 ounce
ELECTRICAL RATING: .............................................................................. 24V - 50/60 Hz, 0.3A