INSTALLATION INSTRUCTIONS
Ins talla tion in struc tions
This appliance is installed on the wall.
Follow the enclosed installation instructions for additional
special accessories (e.g. for circulating-air mode).
Thesurfaces oftheappliance aresensitive. Avoid damaging
them during installation.
Safety notes
ã=Mortal danger, risk of intoxication!
Due to combustion gases sucked back in. Never operate the
appliance in the exhaust air mode at the same time as a room
air-dependent heat-producing appliance unless an adequate
supply of fresh air is ensured.
Room air-dependent heat-producing appliances (e.g. gas, oil,
wood or coal-operated heaters, continuous flow heaters or
water heaters) obtain combustion air from the room in which
they are installed and discharge the exhaust gases into the
open through an exhaust gas system (e.g. a chimney).
In combination with an activated vapour extractor hood, room
air is extracted from the kitchen and neighbouring rooms - a
partial vacuum is produced if not enough fresh air is supplied.
Toxic gases from the chimney or the extraction shaft are
sucked backed into the living space.
Adequate incoming air must therefore always be ensured.
An incoming/exhaust air wall box alone will not ensure
compliance with the limit.
Safe operation is possible only whenever the partial vacuum in
the place where the firing equipment is installed does not
exceed 4 Pa (0.04 mbar). This can be achieved whenever the
air needed for combustion is able to enter through openings
that cannot be sealed, for example in doors, windows,
incoming/exhaust air wall boxes or by other technical means.
In any case, consult your responsible chimney sweep. He is
able to assess the house's entire ventilation setup and will
suggest the suitable ventilation measures to you.
Unrestricted operation is possible if the vapour extractor hood
is operated exclusively in the recirculation mode.
ã=Risk of fire!
from flying sparks. Do not install appliance above a solid fuel
heater (e.g. wood or coal) unless a closed, non-removable
cover is available.
For the installation observe the currently valid building
regulations and the regulations of the local electricity and gas
suppliers.
ã=Risk of electric shock!
from damaged connection cable. Do not kink or pinch
connection cable during installation.
ã=Risk of injury!
From sharp edges during installation. Always wear protective
gloves while installing the appliance.
ã=Risk of injury!
from a falling appliance. All safety screws and safety caps must
be firmly fitted.