Control Technology
13-14
PEAD/
PEA
Main screen Zone control screen
Zone Controller for PEAD/PEA Series
PAC-ZC40/80L-E
PAC-ZC40/8 0H-E
New
Control operation of up to 8 dampers
By controlling the operation of up to eight dampers, the waste of
operating air conditioning in unoccupied areas and areas where it is not
needed can be prevented. Detailed control makes it possible to set
operation to suit the user's needs.
LED indicator
The LED indicator in the lower part of the controller clearly shows the
operation mode. Easily conrm if the air conditioning is on or o from a
distance.
*Set to all green display before shipping.
Easy to see and use
A large, full-dot liquid-crystal screen is incorporated, greatly simplifying
touch panel operation.
The backlight makes operation in dark rooms possible.
Schedule setting
Built-in weekly schedule function can control turning air conditioner on
and o, and opening and closing of each damper. Up
to eight patterns can be set for each week, enabling operation
suitable for each time zone to be set.
Night setback function is incorporated. If the room temperature
is outside of the temperature range setting, heating or cooling
operation starts automatically. This can prevent condensation or
excessive temperature rise in the room.
Wi-Fi compatibility
Can be operated from tablet, smartphone, etc.
Occupancy and brightness sensors
The controller is equipped with a occupancy and brightness sensors that
are used to determine if the room is occupied. When no one is in the
room, operation switches to energy-saving mode. Excellent for ensuring
that the air conditioning gets turned o, and thereby contributing to
further energy savings.
Actual size: 120×140×25mm
(
H×W×D
)
<
Example
>
<
Occupancy sensor
>
<
Energy-saving mode
>
<
Zone controller
>
Detection distance, right/left detection angle
Up/Down detection angle
PAR-ZC01M-E
remote controller
11°
10m
31°
20°
Floor
10m
10m
Wall
110°
PAR-ZC01M-E
remote controller
Brightness sensor
If room light is on, energy-saving control is deactivated.
Occupancy sensor
Judges whether or not someone is in the room by detecting
human motion. If the room is unoccupied, air conditioning is
switched to Energy-saving mode.
Touch panel with backlight
A 4.3-inch touch-panel liquid-crystal screen with a backlight
has been incorporated.
Temperature sensor
Monitors the temperature near the remote controller.
LED indicator
Indicates the operation mode or room temperature using
colours.
*Setting is required.
Operation of up to 8 dampers and occupancy
and brightness sensors provides greater comfort
while improving energy-saving performance.
Touch panel
PAC-ZC40H-E
PAC-ZC80H-E
PAC-ZC40L-E
PAC-ZC80L-E
4 zones (max.)
8 zones (max.)
4 zones (max.)
8 zones (max.)
<
Optional parts
>
Wi-Fi Control Interface
Remote Sensor
Zone Remote Controller
240Volt
240Volt
24Volt
24Volt
MAC-558IF-E
PAC-SE41TS-E
PAR-ZC01M-E
Energy-saving mode settings can be selected (see table below).
Veranda
Living
Oven
Dining
Bed 2
Home theater
Master suite
Media
Entry
WR
WIP
Kitchen
Porch
Robe
Robe
Robe
Bed 4
Bed 3
The damper is closed.
When “Zone control” mode is selected among the energy-saving
mode settings shown below.
Air outletAir intake
Deactivate Even if no one is detected, Energy-saving mode is not set.
Temperature
setting slide
Use slide to set desired temperature from presently
set temperature.
Reduce airow Set airow to “Low”.
Operation/Stop Stop operation.
Zone control Turn o target zone settings.
110°