Loading ...
Loading ...
Loading ...
19
PCA Series
20
PKA Series
PKA-RP71/100KAL
optional standard
Wall-
mounted
Quick Clean Grille
The intake grille lter can easily slide out completely, allowing easy
cleaning without any special tools making it easy to clean in minutes, washing
in water.
Closing automatically when the air conditioner is not running creating a
at surface that is aesthetically appealing.
4-way Piping Provides More Flexibility
in Selecting Installation Sites
Wired Remote Controller Available
(Option)
A separately sold wired remote controller and a terminal block are
available to suit various installation sites.
Drain Pump Option Available with
All Models
Installation of the drain pump enables a drain outlet as high as
800mm above the base of the indoor unit. Drain water can be
discharged easily even if the surface where the wall-mounted unit
does not have direct access outside, increasing the degree of freedom
for installation.
Elegant design and compact dimensions are
ideal for offices
and stores
Auto-flap Shutter
Front grille
Filter
800mm
Drain pump
Indoor unit
Indoor unit
Specications: Wall-mounted
(
PKA
)
PKA-RP71KAL
PUHZ-RP71VHA5
Cooling Heating
PKA-RP100KAL
V: Single-phase, 50Hz, 230V Y: Three-phase, 50Hz, 400V
20-23-26
333-383-433
41-45-49
365
1,170
295
21
18-20-22
300-333-367
39-42-45
PUHZ-RP100V/YKA2
Cooling Heating
10.0 (4.9-11.4) 11.2 (4.5-14.0)
2.90 3.10
3.45 3.61
7.1 (3. 3-8.1) 8.0 (3.5-10.2)
1.96 2.13
3.62 3.76
Outdoor unit
Function
Capacity (min.-max.)
Input
Rated EER/COP
3.20/3.17 3.34/3.313.42 3.56Rated AEER/ACOP
Power supply
Airow
(
Lo-Mid-Hi
)
Sound pressure level
Dimensions Width
Depth
Height
(
kW
)
(
kW
)
L/S
(
dB
)
(
kg
)
(mm)
(mm)
(mm)
Weight
CMM
PCA-RP50/60/71/100/125/140KAQ
optional
Ce iling-
suspended
A stylish indoor unit design and airflow
settings for
both high- and low-ceiling
interiors expand installation possibilities
Stylish Indoor Unit Design
A stylish square-like design is adopted for the
indoor units of all models. As a result, the
units blend in better with the ceiling.
PCA-GA
PCA-KA
Optional Drain Pump for
Full-capacity Models
The pumping height of the optional drain
pump has been increased from 400mm to
600mm, expanding exibility in choosing
unit location during installation work.
Drainage outlet can
be 600mm above
ceiling surface
Drain pump installation
possible
Ceiling
surface
Equipped with Automatic Air-speed Adjustment
In addition to the conventional 4-speed setting, units are now
equipped with an automatic air-speed adjustment mode. This setting
automatically adjusts the air-speed to conditions that match the
room environment. At the start of heating/cooling operation, the
airow is set to high-speed to quickly heat/cool the room. When the
room temperature reaches the desired setting, the
airow speed is de-
creased automatically
for stable comfortable
heating/cooling oper-
ation.
Start of
cooling/heating…
After room
temperature is stabilised…
Strong Gentle
Fresh Outside-air Intake
Units are equipped with a knock-
out hole that enables the induction
of fresh outside-air.
Airow volume (m
3
/min)
50
0
–50
–100
–150
–200
–250
–300
0 1 2 3 4
Static pressure (Pa)
l Outside-air intake characteristics
PCA-RP100140KA
PCA- R P60/71KA
PCA-RP50KA
Capacity
High
ceiling
Standard
ceiling
Low
ceiling
50
60
71
100
125
140
3.5m
3.5m
3.5m
4.2m
4.2m
4.2m
2.7m
2.7m
2.7m
3.0m
3.0m
3.0m
2.5m
2.5m
2.5m
2.6m
2.6m
2.6m
Equipped with High- /Low-ceiling Modes
Units are equipped with high- and
low-ceiling operation modes that
make it possible to switch the air-
ow volume to match room height.
The ability to choose the optimum
airow volume makes it possible to
optimise the breezy
sensation felt
throughout the room.
Indoor unit
Specications: Ceiling-suspended (PCA)
PCA-RP50KAQ
SUZ-KA50VAD
Cooling Heating
PCA-RP60KAQ
SUZ-K A60VAD
Cooling Heating
PCA-RP71KAQ
167-183-217-250 250-267-283-317 267-283-300-333
32-34-37-40
960
25
33-35-37-40
1,280
35-37-39-41
SUZ-K A71VAD
Cooling Heating
4.9 (2.3-5.6) 5.5 (1.7-7.2) 5.7 (2.3-6.3) 6.9 (2.5-8.0) 7.1 (2.8-8.1) 7.9 (2.6-10.2)
1.49 1.68 1.67 2.02 2.06 1.96
3.29 3.27 3.41 3.42 3.45 4.03
PCA-RP71KAQ
PUHZ-RP71VHA5
Cooling Heating
PCA-RP100KAQ
PUHZ-RP100V/YKA2
Cooling Heating
PCA-RP125KAQ
PUHZ-RP125V/YKA2
Cooling Heating
PCA-RP140KAQ
PUHZ-RP140V/YKA2
Cooling Heating
10.0 (4.9-11.4) 11.2 (4.5-14.0) 12.0 (5.5-14.0) 14.0 (5.0-16.0) 13.0 (6.2-15.3) 16.0 (5.7-18.0)
2.63 3.02 3.66 3.88 3.97 4.43
3.80 3.71
7.1 (3. 3-8.1) 8.0 (3.5-10.2)
1.96 2.21
3.62 3.62 3.28 3.61 3.27 3.61
V: Single-phase, 50Hz, 230V Y: Three-phase, 50Hz, 400V
367-400-433-467 383-417-450-483 400-433-483-533
37-39-41-43 39-41-43-45 41-43-45-48
230
1,600
680
36
10-11-13-15 15-16-17-19 16-17-18 -20 22-24-26-28 23-25-27-29 24-26-29-32
32 38 39
Outdoor unit
Function
Capacity (min.-max.)
Input
Rated EER/COP
3.22 3.22 3.35 3.36 3.39 3.96 3.50/3.47 3.46/3.433.42 3.44 3.09/3.07 3.41/3.39 3.10/3.08
4.19/4.11 3.91/3.85
3.41/3.39Rated AEER/ACOP
Power supply
Airow
(
Lo-Mi2-Mi1-Hi
)
Sound pressure level
Dimensions Width
Depth
Height
(
kW
)
(
kW
)
L/S
CMM
(
dB
)
(
kg
)
(mm)
(mm)
(mm)
Weight
* MEPS compliant at part load
* SUZ-K A
VAD is potentially demand response capable unit. DRC-101A is required.
AEER/ACOP (part-load %)
]
Sound Pressure Level
• Sound pressure measurements were conducted in an anechoic chamber.
• The actual noise level depends on the distance from the unit and the acoustic environment.
Sound Pressure Level
• Sound pressure measurements were conducted in an anechoic chamber.
• The actual noise level depends on the distance from the unit and the acoustic environment.
Loading ...
Loading ...
Loading ...