Rinnai 12 Energysaver Operation & Installation Manual
SETTING THE CLOCK
Setting the Clock/Timers
When the appliance is first plugged in or after a power failure, the Digital Display with show --:--
As an example, let’s set the clock to 10:35 am:
1. Press the Set Times button once, the Clock/Timer indicator will flash.
2. Press and hold the “ button; the minutes will begin to change first then the time will change by whole
hours.
3. Release the button when AM 10:00 shows on the Digital Display . Confirm that you have selected AM, a small
indicator on the left hand side of the Digital Display indicates the AM setting.
4. Press and hold the “ button again, release the button when AM 10:35 shows. If you go past AM 10:35,
then the “ button can be used to change the time settings in reverse.
5. Press the Set Times button five times to lock in and complete setting the time. The Clock and Timer indicators
will go out. A small indicator on the Digital Display will flash to show that the Clock is operating.
6. The display will dim approximately 10 seconds after the last control input.
Day light saving and time adjustment
Follow steps 1 to 5 to adjust for day light saving and for time adjustment.
Setting the ON / OFF Timers
Example: programming Timer 1 to heat the room by 7:10 am and finish at 9:00 am.
1. Press the Set Times button twice. The Digital Display will show AM 6:00. The Clock/Timer indicator will
flash.
2. Press the “ button until AM 7:00 appears, release the button, then press it again until AM 7:10 appears.
(Press the “ button if you go past AM 8:00).
3. Press the Set Times button again, the Timer 1 ‘OFF’ indicator will flash. Press the “ button until AM
9:00 appears.
4. Press the Set Times button three times to lock in the program time. The Digital Display will show the
current time. A small indicator on the Digital Display will flash to shown that the display has returned to the
clock.
5. Timer 2 is programmed in the same way. Remember to ensure that the Timer indicator is flashing when you
program in the desired setting.
Before programming the Timers you must ensure that the clock has been set to the
correct time.
This procedure is for setting the ‘ON’/ ‘OFF’ times for Timers. To program the time periods
refer page 13.
If during setting no buttons are pressed for 1 minute the setting sequence will
automatically cancel and the display will revert to normal display.