4. Remove the air chute held in place with one screw.
5. Remove baffle from air chute.
6. Rotate baffle and reinsert it back into the air chute so that the
baffle tabs fit all the way into slots in the air baffle. This will
close off the airflow through the non-vented slots on top of
the hood.
7. Replace air chute.
8. Connect light assembly wiring connector and replace light
panel.
NOTE: Make sure not to trap wires between the support fin and
light panel.
9. Remove either top or rear rectangular knockout. If using
7" (17.8 cm) round vent, remove both top rectangular
knockout and the semicircular knockout.
10. Install damper.
Rectangular vent only:
Attach damper/vent connector over knockout opening. Make
sure damper pivot is nearest to top/back edge of hood. Remove
tape from damper flap.
NOTE: For horizontal vent systems, it is recommended that the
rectangular ventwork be attached to the damper/vent connector
and sealed with vent clamps before installing the hood.
Round vent only:
Replace round vent plate removed in step 1 of “Prepare the
Hood” section.
Install a 7" (17.8 cm) round damper (must be purchased
separately). The damper flap must open freely in the direction on
airflow (away from range hood).
NOTE: Damper/vent connector and round vent plate can be
installed up to 1" (2.5 cm) on either side of hood center if
ventwork is off-center. In extreme off-center installations, one
end of the vent connector may need to be trimmed to clear the
electrical strain relief.
A. Air chute
A. Baffle
A. Tab slots
B. Tabs
A
A
A
B
A. Semicircular knockout
B. Top rectangular knockout
C. Rear rectangular knockout
A. Up to 1" (2.5 cm) side to side adjustment
B. Pivot
C. Damper/vent connector
C
B
A
B
A
B
C
C
Vertical vent
position
Horizontal vent
position