WARNING
All U.S. models are designed for a 3-wire system connection. The dryer frame is
grounded to the neutral conductor at the terminal block. A 4-wire system connection
is required for new or remodeled construction, mobile homes, or if local codes do not
permit grounding through neutral. If you use the 4-wire system, you cannot ground the
dryer frame to the neutral conductor at the terminal block.
Remove the terminal block cover plate. Insert the power cord with a UL-listed strain
relief through the hole provided in the cabinet near the terminal block.
A strain relief must be used. Do not loosen the nuts already installed on the terminal
block. Be sure they are tight. Use a 3/8” (1 cm) deep well socket.