Installation and connection en
9
Converting the cooktop from Nat. Gas to
Universal LPG
All work involved in installation, setting and adaptation
to a different gas type must be carried out by
authorised personnel from our Service Centre and must
comply with current regulations and the conditions laid
down by the local gas company.
Before conversion the cooktop must be disconnected
from the electricity and gas valves must be turned to the
OFF position.
Important: After finishing, stick the sticker, indicating
the new gas type, close to the specifications plate.
Replacing the injectors
Request change-over injectors from our customer
service deparment (refer injector chart below for sizes).
1. Remove all pan supports, burner caps and
distributors.
2. To replace the injectors, use the key that is available
from our technical service with code 340847 (for
double-flame burners 340808). See table. It is
important to make sure that the injector does not
become detached during removal or fastening. They
must be properly tightened to ensure that there are
no leaks.
With these burners, there is no need to adjust the
primary air.
3. Fasten the distributors and burner caps to the
corresponding burners. In addition to this, put the
pan supports in place on the corresponding burners.
Adjusting the gas valves
1. Turn the control knobs to the lowest setting.
2. Remove the control knobs from the gas valves. A
flexible rubber sealing ring will be visible. Push down
with the tip of a screwdriver on the gas valve's
setting screw.
Never remove the sealing ring. Sealing rings
prevent liquids and dirt from finding their way into the
appliance and impairing its ability to function properly.
3. If necessary, use a Torx screwdriver to adjust the
bypass screws:
A: For ULPG the bypass screws must be tightened
properly.
B: For Natural Gas the bypass screws must finish
flush with the fitting.
Make sure that the flame does not go out and that
there are no flashbacks when you turn the control
knob between the highest and lowest setting.
Never remove the gas tap axle. In the event of damage,
the gas valve must be completely replaced.
Natural Gas Universal LPG
Hourly Gas
Consump-
tion (MJ)
Injector
mark
Hourly Gas
Consumption
(MJ)
Injector
mark
Economy
burner
4 88 3,5 50
Standard- out-
put burner
6,85 116 6 66
High-output
burner
11 153 11 87
Mini-wok
burner
13,6 168 12,1 91
Wok burner
4 kW
15 181 15 102
7