1) Description of the control unit :
Mode cursor. Temperature adjustment control dial. V1 Heating indicator light
2) Fixing the comfort temperature
The comfort setting is the temperature that is preferred during times the rooms is occupied.
a) Slide the switch cursor to .
b) Ajust the control dial to the preferred position, the heating light V1 indicates if the temperature drops below the preferred
on the control dial .
c) Wait a few hours for the temperature to stabilise.
d) If the setting is satisfactory (if necessary use a thermometer to check), mark the position for future use.
e) If the setting is not satisfactory, adjust it and start again from point c.
3) Fixing the Eco temperature :
The Eco setting reduces the temperature setting by 3 to 4 degrees. The Eco setting can be used when the room is unoc-
cupied for more than 2 hours.
a) Slide the switch to .
b) Adjust the control dial to the preferred position, the heating light V1 indicates if the temperature drops below the
temperature set on the control dial .
c) Wait a few hours until the temperature stabilizes.
Note : When switching n°1 (on the picture) is set on Programming system (clock symbol) with the PassProgram
On/Off, please refer to paragraph n°8.
4) Frost-Free mode
This mode is used to keep the temperature at approximately 7°C in the room when you are absent from the house for
a prolonged period (i.e. more than 24 hours).
a) Set the switch on .
5) The heating indicator : V1
This light comes on when the heating element is working. It may ash when the temperature has stabilised.
6) Locking the controls :
It is possible to lock or limit use of the control dial and lock the switch to prevent unauthorised manipulation of
the panel heater (children, etc.).
a) Unhook the panel heater from its wall mounting.
b) Remove the pins P on the back of the thermostat casing.
c) Select position B to lock the control dial or position L to limit the amount it can be turned. Position M blocks the switch
for Electronic Model.
7) Using the pilot wire :
The product with pilot wire can receive the following signals from a master unit :
- comfort (temperature of control dial)
- eco (comfort temperature -3°C to -4°C)
- frost free (approximately 7°C)
- off.
Put the switch to the programming mode .
The product must be connected through the pilot wire to a programming control or a product equipped with pass program
system in order to use these different modes. You can control several convectors with a single programmer or a product
equipped with pass program system.
Warning: When the programme turns to Frost Free or Off in the main programming system or using a Pass Program system,
these functions will override the manual switch of the Panel Heater.
8) Using the On/Off PassProgram system. Ref 602019
When using programming mode (clock symbol) with the on/off pass program system (interface + timer), the moon symbol
on the timer refers to the off mode (no heating).
Important : If the timer (602019) is set to off, this function will override the slide switch 1 modes (eco, comfort & frost free)
on the heater.
- There is no point in setting maximum heating, the room temperature will not rise any quicker.
- When you air the room, disconnect the panel heater by putting the switch to off .
- If you leave the room for several hours slide the switch to eco position.
Absence for: less than 2 hours, set the cursor switch knob to moon .
2 to 24 hours, either you can lower the control dial by two graduations, select eco mode or switch to off .
- If you have several units in a room, let them operate simultaneously. This will give you a more uniform temperature without
increasing electricity consumption.
USING THE PANEL HEATER
RECOMMENDATIONS FOR USE