46
FEATURES AND CONTROLS
Instrument Cluster
Diagnostic Display Code Definitions
Open Load: There is a break in the wires that lead to the item listed in
the chart (injector, fuel pump, etc.), or the item has failed.
Short-to-Ground
: The wire is shorted to ground between the electronic
control unit and the item listed in the chart.
Shorted Load
: The wires leading to the item listed in the chart are
shorted together, or the item has shorted internally.
Short-to-Battery
: The wire leading from the item listed in the chart to
the electronic control unit is shorted to a wire at battery voltage.
Diagnostic Codes
Component Condition SPN FMI
Accelerator
Position 2
Data Erratic, Intermittent Or Incorrect 29 2
Voltage Above Normal, Or Shorted To High Source 29 3
Voltage Below Normal, Or Shorted To Low Source 29 4
Throttle Position
Sensor 1
Data Valid But Above Normal Operational Range - Most
Severe Level
51 0
Data Valid But Below Normal Operational Range - Most
Severe Level
51 1
Data Erratic, Intermittent Or Incorrect 51 2
Voltage Above Normal, Or Shorted To High Source 51 3
Voltage Below Normal, Or Shorted To Low Source 51 4
Abnormal Rate Of Change 51 10
Out Of Calibration 51 13
Vehicle Speed
Sensor
Data Valid But Above Normal Operational Range - Most
Severe Level
84 0
Data Valid But Below Normal Operational Range - Most
Severe Level
84 1
Data Erratic, Intermittent Or Incorrect 84 2
Voltage Above Normal, Or Shorted To High Source 84 3
Voltage Below Normal, Or Shorted To Low Source 84 4
Abnormal Frequency Or Pulse Width Or Period 84 8
Abnormal Update Rate 84 9
Abnormal Rate Of Change 84 10
Bad Intelligent Device Or Component 84 12
Received Network Data In Error 84 19
Accelerator
Position 1
Data Erratic, Intermittent Or Incorrect 91 2
Voltage Above Normal, Or Shorted To High Source 91 3
Voltage Below Normal, Or Shorted To Low Source 91 4
Manifold Absolute
Pressure Sensor
Data Erratic, Intermittent Or Incorrect 102 2
Voltage Above Normal, Or Shorted To High Source 102 3
Voltage Below Normal, Or Shorted To Low Source 102 4
Mechanical System Not Responding Or Out Of Adjustment 102 7
Abnormal Rate Of Change 102 10