DESCRIPTION AND USE OF HOOD
1. Control panel
a. Light switch.
b. Extraction and minimum extraction speed ON/OFF switch.
c. Medium extraction speed switch.
d. Maximum extraction speed switch.
2. Grease lter
3. Grease lter release handle
4. Halogen bulb
5. Steam deector
6. Telescopic ue
7. Air outlet (for lter version only)
MAINTENANCE
GREASE FILTERS.
Metal grease lters have an unlimited life and should be washed once a month either by hand or in a dishwasher at a low temperature and
with a short cycle.
Washing in a dishwasher can cause grease lters to turn white, but this in no way aects eciency.
a. press the handle to remove the lter
b. remove it.
Wash the lter and leave it to dry, proceeding in reverse order to ret it.
Halogen lamps:.
Use a small athead screwdriver or any other tool ideal for lifting away objects.
Remove the old light bulb and replace with a new one.
Lamp
Power
(W)
Socket
Voltage
(V)
Dimension
(mm)
ILCOS D Code
(according IEC 61231)
10 G4 12
10 (Diameter)
22( Light Center
Length)
HSGST/C/UB-10-
12-G4-10/22
Follow package directions and do not touch new light bulb with bare hands.
Slot back into place.
ACTIVE CARBON FILTER (lter models only):
The carbon lter must be washed once a month in a dishwasher at the highest temperature, using a normal
dishwasher detergent. Wash the lters on their own.
After washing, reactivate the carbon lter by drying it in the oven at 100° C for 10 minutes.
Change the carbon lter every 3 years.
Fitting the carbon lter:
1. Remove the grease lter.
2. Remove the lter holder by turning the knobs through 90°.
3. Fit the carbon lter iinside the lter holder “h”.
Reverse the above procedure to re-t the lter holder and grease lter.