Installation and connection aus
33
Fresh water connection
1. Connect the fresh-water connection
to the tap according to the
installation instructions with the
enclosed parts.
Ensure that the fresh-water
connection is not kinked, crushed or
twisted.
2. When replacing the appliance,
always use a new water supply hose.
Water pressure:
at least 0.05 MPa (0.5 bar), maximum
1 MPa (10 bar). At a higher water
pressure: connect pressure-reducing
valve ahead.
Inlet rate:
minimum 10 litres/minute
Water temperature:
for cold water connection only.
Electrical connection
Connect the appliance to an
alternating current only, ranging from
220 V to 240 V and 50 Hz or 60 Hz
via a correctly installed socket with
protective earth conductor. See
rating plate for required fusing 9*.
The socket must be near
the appliance and freely accessible
following installation.
If the plug is not freely accessible, an
allpole disconnector with a contact
opening of at least 3 mm must be
fitted on the installation side
to satisfy the relevant safety
instructions.
The connection may be modified by
technicians only.
A power cord extension may be
purchased from customer service
only.
Use only a residual current operated
circuit-breaker which features
the symbol . Only this extension
guarantees compliance with
the currently valid regulations.
The appliance features a water
damage protection system. Please
note the system will not function
unless the power supply
is connected.