Prepare and install
the hood
3-1/4" x 10" (8.3 x 25.4 cm)
RECTANGULAR VERTICAL
vent system
5
4.
From the diagrams below,
select the diagram for your
installation.
Vented installations: Cut the vent
system and electrical wiring
access holes as required. Either
wiring hole can be used.
Non-vented installations: Cut only
the one 1-1/4" (3.2 cm) dia. wiring
access hole required. If wiring
through the top, use location
shown in VERTICAL vent systems.
If wiring through the back, use
location shown in HORIZONTAL
vent system.
5.
Remove terminal box cover.
Depending on your installation,
remove either back or top wiring
knockout.
6.
Remove the rectangular
damper/vent connector from
under the left side of hood. Set
connector and screws aside for
use if connecting to a rectangular
vent system.
For vented installations, go to
Step 7a.
For non-vented installations,
go to Step 7e.
1-1/2"
(3.8 cm)
5-1/2"
(14 cm)
centerline
wall
5-1/4"
(13.3 cm)
7-1/2"
(19.1 cm)
Insert damper/vent connection
through wall
cutout and
into vent
2"
(5.1 cm)
1-1/4"
(3.2 cm)
dia. hole
3-1/4" x 10" (8.3 x 25.4 cm)
HORIZONTAL
vent system
1/8"
(3.2 mm)
3-3/4"
(9.5 cm)
centerline
cabinet
front
5-1/4"
(13.3 cm)
7-1/2"
(19.1 cm)
3/4"
(1.9 cm)
1-1/4" (3.2 cm)
dia. hole
7" (17.8 cm)
ROUND VERTICAL
vent system
5"
(12.7 cm)
centerline
wall
7-1/2"
(19.1 cm)
2"
(5.1 cm)
1-1/4"
(3.2 cm)
dia. hole
8" (20.3 cm)
dia. hole
Excessive Weight Hazard
Use two or more people to move
and install range hood.
Failure to do so can result in
back or other injury.
WARNING
terminal
box
cover
7a.
For vented installations:
Insert the baffle plate into slot
behind grille. The locator bumps
should be at the top as shown.
Remove either top or rear
rectangular vent knockout. If
using round vent, remove both
top rectangular and semi-circular
knockouts.
7b.
Vertical rectangular vent:
Attach the damper/vent
connection with two screws as
shown.
7d.
Vertical round vent:
Fasten the round adapter to the
hood with two screws as shown.
Install round damper (purchased
separately).
7e.
For non-vented
installations:
Check that the baffle
plate has not been installed in
slot behind grille. If it has,
remove the baffle plate
7c.
Horizontal rectangular
vent: Attach damper/vent
connection to back of hood and
insert through the wall cutout and
into the horizontal vent.
Note: If the wall cap is directly
behind the vent connector, the
dampers in the wall connector
and cap MUST NOT interfere with
each other. Remove the vent
connector damper if they interfere.