Loading ...
Loading ...
Loading ...
8
6. Remove terminal box cover and set aside.
7. Remove knockout from the back of the range hood and install
a UL listed or CSA approved ¹⁄₂" (1.3 cm) strain relief.
8. Place the range hood near its mounting position and run the
power supply cable through the strain relief into terminal box
(enough to make connection).
9. Tighten the strain relief screws.
NOTE: Your range hood requires you to purchase either an
internal type or an in-line (external type) blower motor system.
For internal blower systems, there are blower motor mounting
parts in the blower motor installation packet that must be added
to the range hood prior to mounting the range hood to the wall.
See the “Install Range Hood Internal Blower Motor” section and
the instructions supplied with the blower motor.
Install Range Hood
The range hood attaches to the wall by the 2 mounting screws in
the wood support mounted to the wall in the “Range Hood
Mounting Screws Installation” section.
1. Using 2 or more people, hang the range hood on the the wall
by placing the slotted holes in the range hood back over the
2 screws mounted to the wood support mounted to the wall.
NOTE: If your installation uses the optional duct cover, the
vent system needs to be connected to the range hood and
the duct cover mounted to the top of the range hood before
tightening the mounting screws. See steps 3 - 5.
2. Push the range hood up into the narrow slots, align the
bottom of the hood to the horizontal line, level the hood, and
tighten the 2 mounting screws.
3. Mark 2 lower mounting hole center point locations. Drill
¹⁄₈" (0.32 cm) pilot holes if the holes are located into wood. If
holes are not located into wood, drill two ³⁄₈"(0.95cm) pilot
holes and insert 10 x 50 mm wall anchors. Install 2 - 6 x
80 mm screws with D5.3 x 20 mm washers into the lower
mounting anchors and tighten.
4. Install 4 - 4.2 x 19 mm screws through the back of the hood
into the wood support and tighten.
5. Connect vent system to hood. Seal all joints with clamps.
NOTE: If your installation uses the optional full-width duct cover,
attach the duct cover to the top of the range hood following the
instructions and using the screws that are provided with the duct
cover. For information on ordering the optional duct cover, see
the “Accessories” section.
Install Range Hood Internal Blower Motor
NOTE: Your range hood requires you to purchase either an
internal type or an in-line (external type) blower motor system.
See “Blower Motor System” in the “Accessories” section.
The internal blower system can be mounted for top venting or
rear venting. For top venting, the mounting bracket and spring
clip that comes with the blower system will mount to the top
panel of the range hood. For rear venting, the mounting bracket
and spring clip that comes with the blower system will mount to
the rear panel of the range hood.
Prepare the Internal Blower System
IMPORTANT: Perform steps 1-4 before mounting the range
hood.
1. Remove grease filters from range hood. See the “Range
Hood Care” section in the Use and Care Guide.
2. Install the motor support bracket using three 4.2 x 8 mm
screws. Screw bracket to the inside top or back (alternate
location on some models), toward the left side of the range
hood.
3. Install motor spring clip using two 4.2 x 8 mm screws. Screw
spring clip to the inside top or back (alternate location on
some models) of the range hood at the proper location for the
selected motor system. Slide the mounting tab of the spring
clip through the slot in the panel and secure with the screws.
Use the inside set of mounting holes for the single motor
system. Use the outside set of mounting holes for the dual
motor system.
A. 4.2 x 8 mm screws (3) for motor support bracket
B. 4.2 x 8 mm screws (2) for motor spring clip
C. Motor support bracket
D. Motor spring clip (single motor assembly location)
E. Motor spring clip (dual motor assembly location)
C
A
D
E
B
Loading ...
Loading ...
Loading ...