importantNotestotheInstaller
1. Readaiiinstructionscontainedintheseinstallation
instructionsbeforeinstallingthewalloven.
2. Removeallpackingmatedalfromtheoven
compartmentsbeforeconnectingtheelectrical supply
to the waft oven.
3. Observe all governing codes and ordinances.
4. Be sure to leave these instructions with the consumer.
5. Oven door may be removed to facilitate installation.
6. THESE OVENS ARE NOT APPROVED FOR
STACKABLE OR SiDE=BY=SIDE iNSTALLATION.
important Note to the Consumer
Keep these instructions with your Owner's Guide for future
reference,
iMPORTANT SAFETY
INSTRUCTIONS
° Be sure your wall oven is installed and grounded
properly by a qualified installer or service
technician.
° This wall oven must be electrically grounded in
accordance with local codes or, in their absence,
with the National Electrlcal Code ANSI/NFPA No.70=
latest edition in United Sates, or with CSA Standard
C22.1, Canadian Electrical Code, Part 1, in Canada.
Stepping, leaning or sitting on the door
of this wall oven can result in serious injuries and can
also cause damage to the wall oven.
° Never use your wall oven for warming or heating
the room. Prolonged use of the wail oven without
adequate ventilation can be dangerous.
The electrical power to the oven must be
shut off while llne connections are being made. Failure
to do so could result in serious injury or death.
1. Carpentry
Refer to figure 1 or 2 for the dimensions applicable to
your appliance, and the space necessary to receive the
oven. The oven support surface may be solid plywood
or similar material, however the surface must be level
from side to side and from front to rear.
2. Adjusting Oven Height
Oven height can be adjusted with 2" (5 cm) wide wood
shims when needed to fit into an existing cabinet cutout
opening, when cutout height exceeds 2713/16" (70.6
cm) for the single wail oven or 491,4 '' (125.1 cm) for
the double wall oven (see Figure 1 or 2). Place shims of
appropriate height beneath the oven side rails.
3. Electrical Requirements
This appliance must be supplied with the proper
voltage and frequency, and connected to an individual,
properly grounded branch circuit, protected by a circuit
breaker or fuse. To know the circuit breaker or fuse
required by your model, see the serial plate to find the
wattage consumption and refer to table A to get the
circuit breaker or fuse amperage.
n_ I B
Appliance Protection Appliance Protection
Rating Watts Circuit Rating Watts Circuit
I H
240V Recommended 208V Recommended
Lessthan 4800W 20A Lessthan 4100W 20A
4800W - 7200W 30A 4100W - 6200W 30A
7200W - 9600W 40A 6200W - 8300W 40A
9600W and + 50A 8300W and + 50A
Table A
Observe all governing codes and local ordinances
1. A 3-wire or 4-wire single phase 120/240 or 120/208
Volt, 60 Hz AC only electrical supply is required on
a separate circuit fused on both sides of the line
(red and black wires). A time-delay fuse or circuit
breaker is recommended. DO NOT fuse neutral (white
wire). Only certain cooktop models may be installed
over certain built-in electric oven models. Approved
cooktops and built-in ovens are listed by the MFG ID
number (see the insert sheet included in the literature
package).
NOTE: Wire sizes and connections must conform with
the fuse size and rating of the appliance in accordance
with the American National Electrical Code ANSI/NFPA
No. 70-latest edition, or with Canadian CSA Standard
C22.1, Canadian Electrical Code, Part 1, and local codes
and ordinances.
An extension cord should not be used
with this appllance. Such use may result in a fire,
electrlcal shock, or other personal injury. If you need a
longer power cord you can purchase a 101(3 m) power
cord kit #903056-9010 by calling the Service Center.
2. These appliances should be connected to the fused
disconnect (or circuit breaker) box through flexible
armored or nonmetallic sheathed cable. The flexible
armored cable extending from the appliance should
be connected directly to the junction box. The
junction box should be located as shown in Figure
1 or Figure 2 and with as much slack as possible
remaining in the cable between the box and the
appliance, so it can be moved if servicing is ever
necessary.
3. A suitable strain relief must be provided to attach
the flexible armored cable to the junction box.
3