Loading ...
Loading ...
Loading ...
18
Dryer
Safety
Operation
Requirements
Parts and
Features
Installation
Instructions
Dryer Use
Appendix
Dryer Care
Troubleshooting
WARNING
Electrical Shock Hazard
When local codes allow, the electrical supply of the dryer
may be connected by means of a new power supply cord
kit, marked for use with a dryer, that is UL listed and rated
at a minimum of 120/240 volts, 30-ampere with three No.
10 copper wire conductors terminated with closed loop
terminals, open-end spade lugs with turned up ends, or
with tinned leads.
Do not reuse a power supply cord from an old dryer.
The power cord electric supply wiring must be retained
at the dryer cabinet with a suitable UL-listed strain
relief.
Grounding through the neutral conductor is prohibited
for (1) new branch-circuit installations, (2) mobile
homes, (3) recreational vehicles, and (4) areas where
local codes prohibit grounding through the neutral
conductor. (Use a 4-prong plug for 4 wire receptacles,
NEMA type 14-30R.)
Electric models - Canada only
A 240 volt, 60Hz AC approved electrical service fused through a
30-ampere fuse or circuit breaker on both sides of the line is required.
All Canadian models are shipped with the power cord attached. The
power cord should be plugged into a 30-ampere receptacle.
In Canada, you may not convert a dryer to 208 volts.
Loading ...
Loading ...
Loading ...