53TROUBLESHOOTING
ENGLISH
Error Codes
Problem Possible Cause Solutions
Error code: tE1 through
tE7
Temperature sensor failure. Turn off the dryer and call for service.
Display shows error
code: PS (electric
dryers only)
Power cord is connected
incorrectly.
Check the connection of the power cord
to the terminal block.
*Flow Sense
TM
indicator
shows four bars during
the drying cycle or the
display shows "d80"
after drying
* This warning light
is not a dryer failure
and is not covered by
the dryer warranty.
Contact a duct cleaning
service to set up an
appointment to have
your exhaust system
cleaned and inspected.
Exhaust system is too long or
has too many turns/restrictions.
Install a shorter or straighter duct run. See
the Installation Instructions for details.
Partial blockage of the ductwork
due to lint buildup or other
foreign object.
Ductwork should be checked/cleaned
immediately. Dryer can be used in this
condition, but drying times will be longer
and energy consumption will increase.
The appliance has detected a
restriction in the external dryer
venting.
If exhaust restrictions are sensed by the
Flow Sense
TM
system, the indicator will
remain on for 2 hours after the end of the
cycle. Opening the door or pressing the
POWER button will turn off the display.
The Flow Sense
TM
indicator remains
active after clearing
the restriction in the
venting.
After clearing the restriction, the
Flow Sense
TM
system requires
multiple, consecutive cycles to
determine that the performance
value has improved before the
Flow Sense
TM
indicator is reset.
If the Flow Sense
TM
indicator remains
active for more than five cycles after
the restriction has been cleared, call for
service.
indicator light is on
during the drying cycle
Lint filter not cleaned properly.
Remove the lint from the filter before
every load. With the lint removed, hold
the filter up to a light to see if it is dirty or
clogged. If it looks dirty, follow the cleaning
instructions. With some loads that produce
high amounts of lint, it may be necessary
to clean the filter during the cycle.