CONTROLS AND OPERATION
This unit has a hybrid control panel with knobs for adjustment and a digital display to
monitor humidity and fan settings.
1. Plug cord into wall receptacle. Your humidifier is now ready for use.
2. Push in on the Power (lower) knob to turn the unit on.
FAN SPEED
3. Rotate the fan speed knob clockwise to increase the speed.
The 4 speed settings will be shown on the LED display.
NOTE: When excessive condensation exists, a lower speed setting
is recommended.
HUMIDITY CONTROL
NOTE: Allow 10 to 15 minutes for the humidistat to adjust to the room when setting up the
unit for the first time.
NOTE: This model has an adjustable humidistat with settings from 25-65%. The
humidistat will turn the humidifier on when the humidity in your home is below the
humidistat setting and will turn the humidifier off when the humidity reaches the
humidistat setting. When set at 65%, the humidifier will operate continuously until
the unit is empty, and the fan turns off.
4. For initial operation, set the humidity knob at a midpoint setting
(45-50% is recommended) and adjust up or down from there to
achieve the desired humidity level. The digital display will show
the desired setting momentarily, and then revert to displaying
the actual humidity.
CONTROL PANEL DISPLAYS:
Several functions of the humidifier can be monitored through the
LED display on the control panel.
REFILL INDICATION:
5. The letter F on the display indicates when the unit is entirely out
of water. The motor will cut off at this point.
FILTER INDICATION:
The filter’s condition is critical to the humidifier’s effectiveness. A
check filter function (CF) will display every 720 hours of operation to
remind the user to check the condition of the wick. Water quality
significantly affects the life of a wick, so replacement of wick may be
required more often if hard water conditions exist.