Installation Instructions
Install the shuto valve on the nearest frequently used drinking water line.
1
SHUT OFF THE MAIN WATER SUPPLY
AND UNPLUG REFRIGERATOR
Turn on the nearest faucet (counterclockwise) long
enough to clear the line of water.
11
Choose a location for the valve that is easily
accessible. It is best to connect into the side of a
vertical water pipe. When it is necessary to connect
into a horizontal water pipe, make the connection to
the top or side, rather than at the bottom, to avoid
drawing o any sediment from the water pipe.
Drill a 1/4” hole in the water pipe (even if using a self-
piercing valve), using a sharp bit. Remove any burrs
resulting from drilling the hole in the pipe. Take care
not to allow water to drain into the drill. Failure to
drill a 1/4” hole may result in reduced ice production
or smaller cubes.
DRILL THE HOLE FOR THE VALVE
2
Fasten the shuto valve to the cold water pipe with the
pipe clamp.
Tighten the clamp screws until the sealing washer
begins to swell.
NOTE: Do not overtighten or you may crush the tubing.
NOTE: Commonwealth of Massachusetts Plumbing
Codes 248CMR shall be adhered to. Saddle valves
are illegal and use is not permitted in Massachusetts.
Consult with your licensed plumber.
FASTEN THE SHUTOFF VALVE
3
Washer
Inlet End
Clamp
Screw
Vertical Cold
Water Pipe
Saddle-Type
Shuto Valve
Pipe Clamp
6
FLUSH OUT THE TUBING
Turn the main water supply on (counterclockwise) and
ush out the tubing until the water is clear.
Shut the water o at the water valve after about
one quart (1 liter) of water has been ushed through
the tubing.
5
CONNECT THE TUBING TO THE VALVE
Place the compression nut and ferrule (sleeve) for
copper tubing onto the end of the tubing and connect
it to the shuto valve.
Make sure the tubing is fully inserted into the valve.
Tighten the compression nut securely.
For plastic tubing from a GE SmartConnect
Refrigerator Tubing kit, insert the molded end of the
tubing into the shuto valve and tighten compression
nut until it is hand tight, then tighten one additional
turn with a wrench. Overtightening may cause leaks.
NOTE: Commonwealth of Massachusetts Plumbing
Codes 248CMR shall be adhered to. Saddle valves
are illegal and use is not permitted in Massachusetts.
Consult with your licensed plumber.
Saddle-Type
Shuto Valve
Compression
Nut
SmartConnect
Tubing
Packing Nut
Outlet Valve
Ferrule (sleeve)
4
ROUTE THE TUBING
Route the tubing between the cold water line and the
refrigerator.
Route the tubing through a hole drilled in the wall or
oor (behind the refrigerator or adjacent base cabinet)
as close to the wall as possible.
NOTE: Be sure there is sucient extra tubing (about 8
feet [244 cm] coiled into 3 turns of about 10[25 cm]
diameter) to allow the refrigerator to move out from
the wall after installation.