9
Installation instructions
Fastening the cooktop to the bench
This cooktop is suppled with fastening brackets (and screws) that will cope with a
bench thickness of 20-50 mm. For benches thicker than 50 mm, recess the underside
to a thickness of 20-50 mm.
Connecting the cooktop to the gas supply
Important!
This cooktop is supplied factory-set for Natural Gas, but is suitable for installation with either
Natural Gas or LPG, provided the injectors appropriate for the gas type are installed. Refer to
the ‘Gas rate and injector size table’ for nominal ratings and appropriate injector sizes, and to
section ‘Converting to a different gas type’.
The gas connection must be carried out by a suitably qualified person according to the relevant
standards.
For Natural Gas, connect the gas supply to the gas pressure regulator supplied with the cooktop.
Adjust the regulator to obtain a test point pressure of 1 kPa (4”W.C.) with the three largest
burners operating at the highest setting.
For LPG, connect the the gas supply to the test point adaptor supplied with the cooktop. Ensure
that the supply pressure is regulated to 2.75 kPa (11” W.C.) See section Converting to a different
gas type’.
Make sure the connection point will be accessible with the cooktop installed.
To enable the gas supply to be readily shut off, make sure the connection is fitted with an
isolating valve close to the cooktop.
Attach the duplicate appliance data label on a surface adjacent to the cooktop, so that it will be
easily read with the cooktop installed.
For instructions on converting the cooktop for use with a different gas type, see section
‘Converting to a different gas type’.
20 mm
50 mm
recessed to
50 mm
Fig.1 Fastening the cooktop to the bench