28
Dimensions
Width x depth x height 595 mm x 584 mm x 820 mm
Weight 85 kg
Hose and cable lengths
Left-hand connection
or
Right-hand connection
Water connection
To prevent leaks or water damage, you must observe the instructions in
this section.
If in doubt, have a technician connect the appliance.
The water supply and drain hoses can be routed to the left of right,
depending on installation conditions.
Do not use a used inlet hose. Only use the inlet hose supplied or one
which was purchased from an authorised specialist retailer.
Water supply
Do not allow the water supply hose to be:
kinked or squashed,
altered or cut (strength no longer guaranteed).
Note the water pressure in the mains supply:
The water pressure should be between 50-900 kPa (0.5-9 bar) (at least
8 litres of water flow out per minute when the tap is turned on).
If the water pressure is higher, a pressure reducing valve must be fitted.
Connect the cold-water supply hose (blue union nut) to the cold water tap
with ¾" pipe thread.
Only tighten plastic screw connections by hand.
Do not remove the filter from the supply hose.
After connecting the water supply hose:
Turn the tap on fully.
Check the connections for leaks.
Dimensions in mm
min.
500
max.
900
min.
500
max.
900
approx. 1200
approx. 1400
approx. 1150
approx. 950
approx. 800
approx.
750
* depends on the model