16
Installation Instructions
LOCATION OF YOUR WASHER
Do Not Install the Washer:
1. In an area exposed to dripping water or outside
weather conditions. The ambient temperature should
never be below 60°F (15.6°C) for proper washer
operation.
2. In an area where it will come in contact with curtains
or drapes.
2QFDUSHW7KHÀRRUMUST be a hard surface with
a maximum slope of 1/2” per foot (1.27 cm per
30 cm). To make sure the washer does not vibrate
RUPRYH\RXPD\KDYHWRUHLQIRUFHWKHÀRRU
NOTE: ,IÀRRULVLQSRRUFRQGLWLRQXVHµLPSUHJQDWHG
SO\ZRRGVKHHWVROLGO\DWWDFKHGWRWKHH[LVWLQJÀRRU
covering.
IMPORTANT:
Minimum Installation Clearances
 :KHQLQVWDOOHGLQDOFRYH6LGHV5HDU
Top = 0” (0 cm)
 :KHQLQVWDOOHGLQFORVHW6LGHV5HDU
Top = 0” (0 cm), Front = 1” (2.54 cm)
 &ORVHWGRRUYHQWLODWLRQRSHQLQJVUHTXLUHG
2 louvers each 60 square in. (387 cm), located 3”
(7.6 cm) from top and bottom of door
ROUGH-IN DIMENSIONS
SIDE
FRONT
27.0”
(68.6 cm)
20.4” (51.9 cm)
ELECTRONIC TRANSPARENT VISOR
2.2”
(5.6 cm)
40.6”*
(103.1 cm)
30.6”
(77.7 cm)
1.6”
(3.9 cm)
40.6”*
(103.1cm)
39.1”
(99.2 cm)
*NOTE: With pedestal, 52.6”
Stacked, 84”