NOTICES
▯ Examples shown are for reference only. Not all fittings,
connectors, nuts, brackets, ties, etc. are supplied to
accommodate every application.
▯ Ensure there are no kinks or crimps along the entire
length of hose.
▯ If installed in an upper floor of a multi-story building,
the dryer should be installed on a drained floor to
prevent water damage to lower floors in the event of a
leak.
Electrical Connections
Power Cord
The attached power cord is a standard NEMA 6-15P
cord and is UL approved and listed in the USA and
Canada. It meets the following requirements:
▯ 208-240 volt rated;
▯ 15 amps.
NOTICES
▯ This appliance is restricted to being powered by the
supplied power cord noted above.
▯ There are two allowable methods to connect the
appliance cord to power:
1.
If the home has an existing 4-prong, 30A Dryer
receptacle use the supplied Power Adapter.
Plug the adapter into the 4-prong receptacle (Line
side) and then plug the Bosch Dryer and Washer
power cords into the adapter (Load side). See
following images of Power Adapter for Line/Load side
locations and appliance cord placement.
NOTICE:
This adapter can only be used with a 4-prong
receptacle. If the home has an existing 3-prong dryer
receptacle it and its complete branch circuit must be
changed to a 4-prong circuit.
2.
Use an existing individual 240V, 15A minimum branch
circuit having a NEMA 6-15R outlet (or choose to have
one installed).
9 WARNING
TO REDUCE RISK OF FIRE OR ELECTRIC SHOCK.
Do not reuse this Power Adapter with a new
purchase of a Dryer. The old Power Adapter must
be discarded with the old Dryer. A new Power
Adapter must be used when a new Dryer is
installed.
ALL ELECTRICAL CONNECTIONS AND CIRCUITS
9 WARNING
ELECTRIC SHOCK HAZARD
▯ Do not pull on the power cord to unplug the
dryer.
▯ Protect the power cord from physical damage
such as being twisted, kinked, pinched, or walked
on.
▯ DO NOT use an extension cord to connect the
dryer to the power supply.
▯ Make sure:
▯ The power cord fits into the outlet/receptacle.
▯ The home’s internal power supply circuit wire size is
sufficient and electrically grounded.
▯ Do not cut, remove or bypass the grounding
prong on the power cord end.
▯ Do not modify the plug provided with the
appliance; if it will not fit the outlet, have a proper
outlet installed by a qualified electrician.
▯ The power cord must only be replaced by a
qualified service provider or licensed electrician
to help avoid a fire/electric shock hazard.
Use only manufacturer recommended
replacement power cords purchased through our
Customer Service department.
▯ Do not use NEMA 14-30P (4-prong) nor 10-30P
(3-prong) power cords on this appliance.
▯ Do not reuse old power cord.
▯ Do not make a sharp bend or crimp wiring or
conductors at connections.