Page 16 of 24 802698 - G4 User Guide - 09.16 - v2.02
NOTE:
Any attempt, during OFF mode, to dispense water, will bring the unit
out of sleep mode. The unit will return to sleep mode after 2 hours of non
use. Please allow sufficient time for the water to reach the set temperature
after disabling the sleep mode.
LCD Screen operation - Section G
LUX (Light) Sensor Calibration:
It is recommended to recalibrate the Lux Sensor after selecting any of the
4 Lux sensor options from the sleep mode menu. Refer to section C, 5-Lux
calibration
Sleep Mode
Light
Level
Time
Delay
State Boiler Chiller
2 Hours-> 68°C N/A 2 Hr Sleep 68°C ON
2 Hours-> OFF N/A 2 Hr OFF OFF OFF
Lux Sensor->68°C Dark N/A Sleep 68°C ON
Lux Sensor-> OFF Dark N/A OFF OFF OFF
Lux or 2 Hr-> 68°C Dark 2 Hr Sleep 68°C ON
Lux or 2 Hr-> OFF Dark 2 Hr OFF OFF OFF
Disable N/A N/A ON ON ON
This mode allows the HydroTap to Go into Energy Saving mode. There are
two options available: ‘Sleep’ mode and ‘ON/OFF’ mode.
To activate the sleep mode:
1.
Press [MENU] button for main
menu.
2.
Press [Setting] button.
3.
If required, Enter your 4 digit
password
4.
Press [Energy Modes] button.
5.
Press [Sleep Modes] button then
in the next screen, use the up and
down arrows to select one of the
7 options, as shown in the table
below.
Energy Modes (Boiling models)
In SLEEP MODE the unit will Go to “Sleep” after a 2hr period of
inactivity. The Boiling water will gradually drop to either 68°C or room temp,
as shown in the table below and the Chilled water will be ON or OFF.
When the period of inactivity passes, the home screen status window will
show “Sleep Mode”.