User Manual - Page 4

For MRV36. Also, The document are for others Dacor models: HRV46, MRV3015S, MRV3615S, MRV48S, MRV3015-ERS, MRV36-ERS, MRV48-ERS

Loading ...
Loading ...
Loading ...
2
Operation
IMPORTANT
The direction of travel of the vent intake cannot be
reversed while it is moving. The intake must complete a
full up or down cycle before changing directions.
To raise the vent, press the button on the top cap. The
intake takes about 10 seconds to raise fully.
Once up, the blower turns on at the speed at which was
set when the intake was last lowered. Adjust blower
speed by turning the variable speed control.
Turn the blower off by pressing the button on the top
cap. The blower turns off, and the intake lowers fully.
Operating Tips
Turn on the downdraft vent a few minutes before cook-
ing to establish airflow in the room.
Adjust fan speed to the volume of the cooking exhaust.
Always operate the vent when using the cooktop.
Operating Your Downdraft Vent
Reduce fan speed if the vent pulls at the cooktop
flame.(This is normal with powerful vent systems,
especially those with short duct runs.)
Eliminate nearby air currents by shutting windows and
doors, turning off ceiling fans, and closing adjacent
heating/air-conditioning outlets.
Place the largest cookware on the rear burners if pos-
sible, as the draft is strongest next to the intake.
Parts the of Downdraft Vent - Shown Raised
Variable
speed
control
Top cap
Countertop
Lower
Higher
Up/Down button
Filters
WARNING
Clean the vent only as specified.
Use only the cleaning solutions listed in this manual.
Before cleaning, turn off the range and vent, and wait
for all surfaces to cool.
Wipe stainless steel with the grain. Do not use
abrasive cleaners or scrubbers.
To avoid fan damage, do not reinstall damaged filters.
Do not clean the filters in a dishwasher.
Cleaning the Top Cap
Clean the top cap when the vent is down.
Gently wipe the cap with a sponge or soft cloth moist-
ened with a mild detergent-water solution. Keep moisture
away from the On/Off button.
Care and Cleaning
4. Wipe surrounding areas (inside and out), with a sponge
or cloth moistened with a mild detergent. Rinse these
surfaces with water. Wipe dry with a soft, dry cloth.
5. Hand-wash the filters in hot water with mild-detergent
solution.
6. Dry the lters completely, then re-install them.
Cleaning the Filters
Clean the filters regularly to prevent grease buildup.
1. Raise the vent.
2. Gently grasp each filter on both sides, and push down.
3.
Pull the top of each filter out and lift away from the vent.
Top cap
Filter
Removal
Loading ...
Loading ...
Loading ...