Kelvinator gas continuous flow hot water systems troubleshooting 11
Troubleshooting
Temperature and amount of hot water
Problem Possible solutions
It takes a long time for hot water to
reach the xtures.
The time it takes to deliver hot water from the water heater to your xtures
depends on the length of piping between the two. The longer the distance or
the bigger the pipes, the longer it will take to get hot water.
The water is not hot enough
If a tempering valve is installed, is it set too low or malfunctioning?
Are the cold water and hot water lines cross connected?
Is the gas supply valve fully open?
Is the gas line sized properly?
Is the gas supply pressure enough?
Is the set temperature set too low?
Is the combustible air inlet or exhaust outlet blocked?
The water is too hot Is the set temperature set too high?
The hot water is not available when a
xture is opened.
Does the water heater have a 240V 50Hz power supply available?
If you are using the remote controller, is the power button turned on?
Is the gas supply valve fully open?
Is the water supply valve fully open?
Is the lter on cold water inlet clean?
Is the hot water xture sufciently open to draw at least 3.0l/min through the
water heater?
Is the water heater frozen?
Is there gas available to the water heater and (if applicable) does the gas
storage tank have enough gas in it?
The hot water gets cold and stays cold
Is the ow rate enough to keep the water heater running?
Is the gas supply valve fully open?
Is the lter on the cold water inlet clean?
Are the xtures clean of debris and obstructions?
Fluctuation in hot water temperature.
Is the lter on the cold water inlet clean?
Is the gas line sized properly?
Is the supply gas pressure enough?
Are the cold water and hot water lines cross connected?
Water heater
Problem Possible solutions
Burner does not ignite when water
goes through the water heater.
Is the ow rate over 3.0l/min?
Is there a 240V 50Hz power supply available to the water heater?
Are the cold water and hot water lines cross connected or reversed?
If you use the remote controller, is the power button turned on?
The fan motor is still spinning after
operation has stopped.
This is normal. After operation has stopped, the fan motor keeps running for
15 – 75 seconds in order to re-ignite quickly, as well as push all exhaust gas
out of the ue.
White vapour clouds are coming from
the hot air outlet of the water heater
It is normal to see water vapour clouds or steam coming from the hot air outlet
of the water heater especially during cold and wet days.
Remote controller (optional)
Problem Possible solutions
Remote controller does not display
anything when the power button is
turned on.
Press the ON/OFF button.
If the lamp does not light:
Make sure the water heater has power supply.
Make sure the connection to the water heater is correct.
An ERROR code is displayed Call a service technician.
Remote controller can not change
the set temperature.
Is priority lamp lit? If it is not, press the priority button after closing all
hot water taps.